본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

정상인에서 이중 샤임플러그 전안부사진기로 측정한 각막윤부직경과 전방 깊이

이용수 7

영문명
Measurement of White-to-White Diameter and Anterior Chamber Depth by Dual Scheimpflug Camera
발행기관
대한안과학회
저자명
한경은 전루민,Kyung-Eun Han, MD, Roo Min Jun, MD, PhD
간행물 정보
『대한안과학회지』Ophthalmological Society,volume51,number2, 169~174쪽, 전체 6쪽
주제분류
의약학 > 기타의약학
파일형태
PDF
발행일자
2010.02.15
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: To estimate the horizontal and vertical white-to-white diameters (WTW) and anterior chamber depths (ACD) with a dual Scheimpflug camera (GALILEI™, Ziemer, Switzerland) and to compare the estimates measured by a measuring caliper and ultrasound biomicroscopy (UBM PlusTM, Paradigm Inc., Utah, USA) in normal subjects. Methods: Forty-four eyes of 23 subjects were evaluated. Corneal diameter as measured by GALILEI was directly compared with the white-to-white diameter (WTW) measured by a caliper and the correlation with ciliary sulcus diameter (STS) by UBM was evaluated. The anterior chamber depth (ACD) as measured by GALILEI™ was compared with the estimates measured by UBM. Results: The horizontal and vertical diameters of WTW by GALILEI were not significantly different from the measurements taken by calipers (p>0.05, p>0.05, respectively), and there were no correlations between the measurements (r=-0.074, p>0.05 at 180o r=0.297, p>0.05 at 90o, respectively). The estimates by GALILEI did not correlate with those measured with UBM (r=-0.006, p>0.05 at 180o r=-0.222, p>0.05 at 90o, respectively). However, the mean ACD by GALILEI was deeper than thatby UBM (p<0.01), and the measurements correlated strongly with each other (r=0.760; p<0.01). Conclusions: The mean WTW measured by GALILEI was not significantly different from the measurements taken by calipers and the measurements did not correlate with each other. There was also no correlation with the measurementsby GALILEI and UBM. ACD by GALILEI was measured to be deeper those that by UBM. J Korean Ophthalmol Soc 2010;51(2):169-174

목차

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

한경은,전루민,Kyung-Eun Han, MD, Roo Min Jun, MD, PhD. (2010).정상인에서 이중 샤임플러그 전안부사진기로 측정한 각막윤부직경과 전방 깊이. 대한안과학회지, 51 (2), 169-174

MLA

한경은,전루민,Kyung-Eun Han, MD, Roo Min Jun, MD, PhD. "정상인에서 이중 샤임플러그 전안부사진기로 측정한 각막윤부직경과 전방 깊이." 대한안과학회지, 51.2(2010): 169-174

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제