본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

정상인에서 시간 도메인과 스펙트럼 도메인 빛간섭단층촬영으로 측정한 황반두께 측정의 반복성 및 일치도

이용수 0

영문명
Repeatability and Agreement of Macular Thickness Measurement Using Time Domain OCT and Spectral Domain OCT in Normal Subjects
발행기관
대한안과학회
저자명
오세범 조원빈 문준웅 김형찬,Se Beum Oh, MD, Won Bin Cho, MD, Jun Woong Moon, MD, Hyung Chan Kim, MD
간행물 정보
『대한안과학회지』Ophthalmological Society,volume50,number5, 710~716쪽, 전체 7쪽
주제분류
의약학 > 기타의약학
파일형태
PDF
발행일자
2009.05.15
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: To compare the repeatability and agreement of macular thickness measurements using time domain (TD) optical coherence tomography (OCT) and spectral domain (SD) OCT in normal subjects. Methods: Thirty-four normal subjects were included. Three consecutive macular measurements were taken with TD OCT and SD OCT. Total and regional macular thickness and total macular volume obtained by the two OCTs were compared. Withinsubject standard deviation (Sw), coefficient of variation (CVw), and the intraclass correlation coefficient (ICC) were calculated to evaluate repeatability. The agreement was examined with Bland Altman plots. The correlation was also evaluated with Pearson correlation coefficients and multiple regression analysis. Results: Sw for foveal thickness, total macular thickness, and total macular volume were 11.53 μm, 7.58 μm, and 0.48 mm3 for TD OCT and 6.69 μm, 2.55 μm, and 0.09 mm3 for SD OCT, respectively. The values for SD OCT were consistently lower, and this result was statistically significant. The range of the respective CVw and ICC values were 1.10~2.78% and 0.78~0.96% for TD OCT, and 0.29~0.94% and 0.92~0.99% for SD OCT, respectively. The SD OCT showed better repeatability for macular thickness measurements(all with p≤0.001). The spans of 95% limits of agreement for foveal thickness, total macular thickness, and total macular volume were 67.94 μm, 29.01 μm, and 0.98 mm3, respectively. The Pearson correlation coefficient of foveal thickness, total macular thickness, and total macular volume between the two OCT’s was statistically significant. Conclusions: Although both OCTs are reliable for macular thickness measurements, SD OCT shows better repeatability compared with TD OCT. Although macular thickness measurements obtained from the two OCTs can not be used interchangeably due to low agreement by different standards of measurement, there was a statistically significant correlation between the two OCT’s

목차

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

오세범,조원빈,문준웅,김형찬,Se Beum Oh, MD, Won Bin Cho, MD, Jun Woong Moon, MD, Hyung Chan Kim, MD. (2009).정상인에서 시간 도메인과 스펙트럼 도메인 빛간섭단층촬영으로 측정한 황반두께 측정의 반복성 및 일치도. 대한안과학회지, 50 (5), 710-716

MLA

오세범,조원빈,문준웅,김형찬,Se Beum Oh, MD, Won Bin Cho, MD, Jun Woong Moon, MD, Hyung Chan Kim, MD. "정상인에서 시간 도메인과 스펙트럼 도메인 빛간섭단층촬영으로 측정한 황반두께 측정의 반복성 및 일치도." 대한안과학회지, 50.5(2009): 710-716

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제