본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

바이모달 보청기 적합 문헌 고찰

이용수 26

영문명
A Review of Bimodal Hearing Aid Fitting
발행기관
한국청각언어재활학회
저자명
오수희(Soo Hee Oh)
간행물 정보
『Audiology and Speech Research』Audiology and Speech Research 제15권 제2호, 71~77쪽, 전체 7쪽
주제분류
사회과학 > 교육학
파일형태
PDF
발행일자
2019.04.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Bimodal hearing refers to the combination of the cochlear implant in one ear and the hearing aid in the opposite ear. Recently, cochlear implant candidacy criteria have been expanded and the number of people receiving cochlear implants with residual hearing has increased, leading to the raised bimodal population. Providing professional fitting services based on systematic bimodal fitting methods or guidelines are essential for the successful bimodal intervention of the hearing impaired. However, there is a lack of evidence-based bimodal fitting method or guideline clinically applicable. In general, bimodal fitting consists of three areas of fitting; cochlear implant mapping, hearing aid fitting, and bimodal fitting. Among them, establishing evidence-based bimodal hearing aid fitting will be a key factor to improve bimodal fitting services of hearing aid centers. The purpose of this study is to review recent literature related to bimodal hearing aid fitting to establish bimodal hearing aid fitting guidelines for hearing aid professionals. This review involves five bimodal hearing aid fitting issues including frequency response, loudness, dynamic compression, frequency transposition, and hearing aid fitting formula. In addition, it described three recent clinical bimodal hearing aid fitting guidelines provided by manufacturers. Two factors contributing to bimodal hearing aid fitting optimization across the studies are frequency response and loudness balance. Conducting loudness balance in bimodal hearing devices and adjusting gains based on the loudness balance tests are one of the important procedures for bimodal fitting optimization. Hearing aid fitting based on wide-band frequency responses and conventional hearing aid formula is recommended for the initial step of the bimodal fitting.

목차

INTRODUCTION
MATERIALS AND METHODS
DISCUSSIONS

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

오수희(Soo Hee Oh). (2019).바이모달 보청기 적합 문헌 고찰. Audiology and Speech Research, 15 (2), 71-77

MLA

오수희(Soo Hee Oh). "바이모달 보청기 적합 문헌 고찰." Audiology and Speech Research, 15.2(2019): 71-77

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제