학술논문
교정용 각형선재에 부여된 torque가 브라켓에 발생시키는 모멘트에 관한 유한요소법적 분석
이용수 13
- 영문명
- The moment generated by the torwue of the orthodontic rectangular wire : Three-dimensional finite element analysis
- 발행기관
- 대한치과교정학회
- 저자명
- 하도원(Do-Won Ha) 김영석(Young-Suk Kim) 성재현(Jae-Hyun Sung)
- 간행물 정보
- 『The Korean Journal of Orthodontics』제31권 제3호, 335~346쪽, 전체 12쪽
- 주제분류
- 의약학 > 기타의약학
- 파일형태
- 발행일자
- 2001.06.30
무료
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.
국문 초록
영문 초록
The purpose of this study was to investigate the ideal clinical torque(In the SWA rectangular wire, the torque by the angle between the plane part and twisted part to move the tooth) of the orthodontic rectangular wire which produce the proper labiongual movement of the single tooth during finishing stage of the orthodontic treatment. The clincal torque is the sum od the play and the active torque which generates the moment at the bracket. The play is calculated by the formual and the active torqe is calculated by the computer aided three-dimensional finite element method. The finite element model was consist of the three brackets which formed a row and 3 kinds of orthodontic rectangular wire(stainless steel, TMA, NiTi) which inserted in brackets. Both sides of the model were twisted and the moment generated in the center was calculated. The sizes od seven wires which were used commonly were .016 X .022 , .017 X .022 , .017 X .025 , .018 X .025 , .019 X .025 , .020 X .025 , .021 X .025 . In .018 bracket, .016 X .022 , .017 X .022 , .017 X .025 wires were inserted and in .022 bracket, all the sizes of wires except .016 X .022 were inserted and tested. The follwing conclusions could be drawn from this study 1. The moments generated on the same size of the wires by the same active torque were equal regardless od the bracket slot size. 2. The moments were increased with the size of the wires. The moment generated on the .021 X .025 wire was about 1.75 times as large as that on the .016 X .022 wire regardless of material. 3. The moments were increased in the order of the NiTi, TMA, stainless steel. The moment of the TMA wire was 0.35 times as smaall as thst of the stainless steel was 0.16 times as small as that of the stainless steel wire. 4. The moment was decreased as the inter bracket distance was increased. 5. To get a desired moment with the specific size and material of the wire on the specific bracket slot, the formula and the results were displayed.
목차
해당간행물 수록 논문
- 아말감 충전물의 크기와 표면 처리방법에 따른 교정용 브라켓의 전단접착 강도에 대한 연구
- 스트렙토조토신 유발 당뇨병 백서에서 실험적 치아이동중의 치조골 교체
- 교정용 각형선재에 부여된 torque가 브라켓에 발생시키는 모멘트에 관한 유한요소법적 분석
- 성견에서 수직적 골결손부에 골이식후 교정력 적용시기에 따른 치주조직의 반응
- Asymmetric Head-Gear의 견인력의 차이에 따른 상악 제 1대구치에 나타나는 힘과 변위 및 초기 응력분포에 관한 유한요서법적 비교 연구
- 상하악 전치부 치열궁 형태에 대한 새로운 접근
- 심미적 측모 판단에 미치는 성별과 문화의 영향력
- 치근 부착 스트레인 게이지를 이용한 응력 분포 분석
참고문헌
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)