학술논문
전신 뼈 스캔의 오류 감소를 위한 프로세스 구축과 적용 효과
이용수 0
- 영문명
- Building the Process for Reducing Whole Body Bone Scan Errors and its Effect
- 발행기관
- 대한핵의학기술학회
- 저자명
- 김동석(Dong Seok Kim) 박장원(Jang Won Park) 최재민(Jae Min Choi) 심동오(Dong Oh Shim) 김호성(Ho Seong Kim) 이영희(Yeong Hee Lee)
- 간행물 정보
- 『핵의학기술』Vol.21 No.1, 76~82쪽, 전체 7쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2017.06.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.
국문 초록
영문 초록
Purpose Whole body bone scan is one of the most frequently performed in nuclear medicine. Basically, both the anterior and posterior views are acquired simultaneously. Occasionally, it is difficult to distinguish the lesion by only the anterior view and the posterior view. In this case, accurate location of the lesion through SPECT / CT or additional static scan images are important. Therefore, in this study, various improvement activities have been carried out in order to enhance the work capacity of technologists. In this study, we investigate the effect of technologist training and standardized work process processes on bone scan error reduction. Materials and Methods Several systems have been introduced in sequence for the application of new processes. The first is the implementation of education and testing with physicians, the second is the classification of patients who are expected to undergo further scanning, introducing a pre-filtration system that allows technologists to check in advance, and finally, The communication system called NMQA is applied. From January, 2014 to December, 2016, we examined the whole body bone scan patients who visited the Department of Nuclear Medicine, Asan Medical Center, Seoul, Korea Results We investigated errors based on the Bone Scan NMQA sent from January 2014 to December 2016. The number of tests in which NMQA was transmitted over the entire bone scan during the survey period was calculated as a percentage. The annual output is 141 cases in 2014, 88 cases in 2015, and 86 cases in 2016. The rate of NMQA has decreased to 0.88% in 2014, 0.53% in 2015 and 0.45% in 2016. Conclusion The incidence of NMQA has decreased since 2014 when the new process was applied. However, we believe that it will be necessary to accumulate data continuously in the future because of insufficient data until statistically confirming its usefulness. This study confirmed the necessity of standardized work and education to improve the quality of Bone Scan image, and it is thought that update is needed for continuous research and interest in the future.
목차
서론
대상 및 방법
결과
고찰 및 결론
요약
참고문헌
해당간행물 수록 논문
- 설문조사를 바탕으로 부서 간 만족도 향상을 위한 개선 안
- Thyroglobulin 검사의 반응조건에 따른 결과 비교 분석
- 방사성 동위원소를 이용한 핵의학과 검사에서 병동 간호사의 방사선 피폭선량 평가
- 대한핵의학기술학회 투고 논문 분류
- 전신 뼈 스캔의 오류 감소를 위한 프로세스 구축과 적용 효과
- Westgard Multi-Rules의 효율적 적용과 조치사항의 개선
- Brain SPECT 검사 시 Dynamic Continuous Mode의 유용성 평가
- 물리적 보정된 핵의학 영상 평가
- PET-CT 검사 시 호흡 동조 시스템들의 유용성 평가
- Thyroglobulin 검사의 반응조건에 따른 결과 비교 분석
- ⁵⁷Co 밀봉선원의 노후도에 따른 균일도의 변동과 중첩사용에 관한 유용성 평가
- PET/CT 검사에서 Flow mode를 적용한 Respiratory Gating Method 촬영과 추가 Gating 촬영의 비교 및 유용성 평가
- 갑상선 섭취율 측정에서 선원의 길이와 부피 증가에 따른 영향
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 의료용 인공지능에 대한 동향 분석 및 방사선사 인식조사
- CT contrast 검사 시 중심 정맥관을 이용한 조영제 사용에 대한 연구
- CT조영제 부작용 고위험군에 대한 전처치의 유용성
의약학 > 방사선과학분야 NEW
- 초음파 조직검사에 사용되는 Biopsy Gun Needle의 재질에 따른 반사율 연구
- 방사선에 대한 지식 및 인식도 연구
- 입원환자 일반촬영 이용량 및 피폭선량: 2018년 입원환자데이터
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!