본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

전신 뼈 스캔의 오류 감소를 위한 프로세스 구축과 적용 효과

이용수 0

영문명
Building the Process for Reducing Whole Body Bone Scan Errors and its Effect
발행기관
대한핵의학기술학회
저자명
김동석(Dong Seok Kim) 박장원(Jang Won Park) 최재민(Jae Min Choi) 심동오(Dong Oh Shim) 김호성(Ho Seong Kim) 이영희(Yeong Hee Lee)
간행물 정보
『핵의학기술』Vol.21 No.1, 76~82쪽, 전체 7쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2017.06.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose Whole body bone scan is one of the most frequently performed in nuclear medicine. Basically, both the anterior and posterior views are acquired simultaneously. Occasionally, it is difficult to distinguish the lesion by only the anterior view and the posterior view. In this case, accurate location of the lesion through SPECT / CT or additional static scan images are important. Therefore, in this study, various improvement activities have been carried out in order to enhance the work capacity of technologists. In this study, we investigate the effect of technologist training and standardized work process processes on bone scan error reduction. Materials and Methods Several systems have been introduced in sequence for the application of new processes. The first is the implementation of education and testing with physicians, the second is the classification of patients who are expected to undergo further scanning, introducing a pre-filtration system that allows technologists to check in advance, and finally, The communication system called NMQA is applied. From January, 2014 to December, 2016, we examined the whole body bone scan patients who visited the Department of Nuclear Medicine, Asan Medical Center, Seoul, Korea Results We investigated errors based on the Bone Scan NMQA sent from January 2014 to December 2016. The number of tests in which NMQA was transmitted over the entire bone scan during the survey period was calculated as a percentage. The annual output is 141 cases in 2014, 88 cases in 2015, and 86 cases in 2016. The rate of NMQA has decreased to 0.88% in 2014, 0.53% in 2015 and 0.45% in 2016. Conclusion The incidence of NMQA has decreased since 2014 when the new process was applied. However, we believe that it will be necessary to accumulate data continuously in the future because of insufficient data until statistically confirming its usefulness. This study confirmed the necessity of standardized work and education to improve the quality of Bone Scan image, and it is thought that update is needed for continuous research and interest in the future.

목차

서론
대상 및 방법
결과
고찰 및 결론
요약
참고문헌

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

김동석(Dong Seok Kim),박장원(Jang Won Park),최재민(Jae Min Choi),심동오(Dong Oh Shim),김호성(Ho Seong Kim),이영희(Yeong Hee Lee). (2017).전신 뼈 스캔의 오류 감소를 위한 프로세스 구축과 적용 효과. 핵의학기술, 21 (1), 76-82

MLA

김동석(Dong Seok Kim),박장원(Jang Won Park),최재민(Jae Min Choi),심동오(Dong Oh Shim),김호성(Ho Seong Kim),이영희(Yeong Hee Lee). "전신 뼈 스캔의 오류 감소를 위한 프로세스 구축과 적용 효과." 핵의학기술, 21.1(2017): 76-82

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제