갑상선 섭취율 측정에서 선원의 길이와 부피 증가에 따른 영향

이용수 0

영문명
The Effect of Increase in Length and Volume of Source in Radioactive Iodine Thyroid Uptake Rate
발행기관
대한핵의학기술학회
저자명
황동훈(Dong Hun Hwang) 오신현(Shin Hyun Oh) 김정열(Jung Yul Kim) 강천구(Chun Koo Kang) 김재삼(Jae Sam Kim)
간행물 정보
『핵의학기술』Vol.21 No.1, 70~75쪽, 전체 6쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2017.06.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose Radioactive iodine thyroid uptake (RAIU) rate is an examination which determines and seeks about general functions of thyroid gland. The size of thyroid gland is normally different between each person, also patients having thyroid diseases have had a variety of size of thyroid gland compared with others. The purpose of this study will investigate about the counting rate which is effected by the geometric factors through the length and volume changes of the source in RAIU rate. Materials and Methods I-131 185 kBq (5 μCi) were placed in a cylindrical phantom of 0.5 cm, 1 cm, 1.5 cm, and 3 cm in diameter, respectively, and saline was added to gradually increase the length by 1 cm in the horizontal and vertical directions to give a change in volume. The source was measured 20 times for 20 seconds from a distance of 25 cm to 364.4 keV±20% energy ROI with Captus 3000 thyroid uptake system (Capintec, NJ, USA). Results When the source was located in the transverse direction of the detector, the consequence of one-way ANOVA is that even though the length of source is increased each diameter, there is mostly no significant difference. When the source was located in the longitudinal direction and the counting rate of length 1 cm at all diameter is set to 100%, the average is 92.57% for length 2 cm, 86.1% for 3 cm, 80.69% for 4 cm, 74.82% for 5 cm, and 69.68% at 6 cm. Conclusion According to this study, it is expected that the gap of RAIU rate has been depended on the thickness of thyroid gland as well as the diameter of the beaker. We know that the change of the volume with the increase of the length of the source had less effect on the change of the counting rate. Thus, in order to reduce the error in the measurement of the counting rate with the thyroid uptake rate equipment, an accurate counting rate can be relatively measured if the counting rate which is measured is corrected by thickness or the distance between the thyroid and the thyroid uptake rate equipment is changed.

목차

서론
실험 재료 및 방법
결과
고찰
결론
요약
참고문헌

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

황동훈(Dong Hun Hwang),오신현(Shin Hyun Oh),김정열(Jung Yul Kim),강천구(Chun Koo Kang),김재삼(Jae Sam Kim). (2017).갑상선 섭취율 측정에서 선원의 길이와 부피 증가에 따른 영향. 핵의학기술, 21 (1), 70-75

MLA

황동훈(Dong Hun Hwang),오신현(Shin Hyun Oh),김정열(Jung Yul Kim),강천구(Chun Koo Kang),김재삼(Jae Sam Kim). "갑상선 섭취율 측정에서 선원의 길이와 부피 증가에 따른 영향." 핵의학기술, 21.1(2017): 70-75

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제