- 영문명
- The Effect of Increase in Length and Volume of Source in Radioactive Iodine Thyroid Uptake Rate
- 발행기관
- 대한핵의학기술학회
- 저자명
- 황동훈(Dong Hun Hwang) 오신현(Shin Hyun Oh) 김정열(Jung Yul Kim) 강천구(Chun Koo Kang) 김재삼(Jae Sam Kim)
- 간행물 정보
- 『핵의학기술』Vol.21 No.1, 70~75쪽, 전체 6쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2017.06.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

국문 초록
영문 초록
Purpose Radioactive iodine thyroid uptake (RAIU) rate is an examination which determines and seeks about general functions of thyroid gland. The size of thyroid gland is normally different between each person, also patients having thyroid diseases have had a variety of size of thyroid gland compared with others. The purpose of this study will investigate about the counting rate which is effected by the geometric factors through the length and volume changes of the source in RAIU rate. Materials and Methods I-131 185 kBq (5 μCi) were placed in a cylindrical phantom of 0.5 cm, 1 cm, 1.5 cm, and 3 cm in diameter, respectively, and saline was added to gradually increase the length by 1 cm in the horizontal and vertical directions to give a change in volume. The source was measured 20 times for 20 seconds from a distance of 25 cm to 364.4 keV±20% energy ROI with Captus 3000 thyroid uptake system (Capintec, NJ, USA). Results When the source was located in the transverse direction of the detector, the consequence of one-way ANOVA is that even though the length of source is increased each diameter, there is mostly no significant difference. When the source was located in the longitudinal direction and the counting rate of length 1 cm at all diameter is set to 100%, the average is 92.57% for length 2 cm, 86.1% for 3 cm, 80.69% for 4 cm, 74.82% for 5 cm, and 69.68% at 6 cm. Conclusion According to this study, it is expected that the gap of RAIU rate has been depended on the thickness of thyroid gland as well as the diameter of the beaker. We know that the change of the volume with the increase of the length of the source had less effect on the change of the counting rate. Thus, in order to reduce the error in the measurement of the counting rate with the thyroid uptake rate equipment, an accurate counting rate can be relatively measured if the counting rate which is measured is corrected by thickness or the distance between the thyroid and the thyroid uptake rate equipment is changed.
목차
서론
실험 재료 및 방법
결과
고찰
결론
요약
참고문헌
해당간행물 수록 논문
- 설문조사를 바탕으로 부서 간 만족도 향상을 위한 개선 안
- Thyroglobulin 검사의 반응조건에 따른 결과 비교 분석
- 방사성 동위원소를 이용한 핵의학과 검사에서 병동 간호사의 방사선 피폭선량 평가
- 대한핵의학기술학회 투고 논문 분류
- 전신 뼈 스캔의 오류 감소를 위한 프로세스 구축과 적용 효과
- Westgard Multi-Rules의 효율적 적용과 조치사항의 개선
- Brain SPECT 검사 시 Dynamic Continuous Mode의 유용성 평가
- 물리적 보정된 핵의학 영상 평가
- PET-CT 검사 시 호흡 동조 시스템들의 유용성 평가
- Thyroglobulin 검사의 반응조건에 따른 결과 비교 분석
- ⁵⁷Co 밀봉선원의 노후도에 따른 균일도의 변동과 중첩사용에 관한 유용성 평가
- PET/CT 검사에서 Flow mode를 적용한 Respiratory Gating Method 촬영과 추가 Gating 촬영의 비교 및 유용성 평가
- 갑상선 섭취율 측정에서 선원의 길이와 부피 증가에 따른 영향
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 민간의료보험 해약 의향 영향 요인: 한국 의료 패널 2019년 2기 자료를 이용하여
- 방사선학과 학생 실습환경에 관한 연구: 실습실 내 미세먼지, 휘발성유기화합물 위해도를 중심으로
- 임상에서 사용되는 온장고 온도설정 및 한계점에 대한 고찰