학술논문
Thyroglobulin 검사의 반응조건에 따른 결과 비교 분석
이용수 0
- 영문명
- Comparison of Results According to Reaction Conditions of Thyroglobulin Test
- 발행기관
- 대한핵의학기술학회
- 저자명
- 정승희(Seung-Hee Joung) 이영지(Young-Ji Lee) 문형호(Hyung-Ho Moon) 유소연(So-yoen Yoo) 김년옥(Nyun-Ok Kim)
- 간행물 정보
- 『핵의학기술』Vol.21 No.1, 39~43쪽, 전체 5쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2017.06.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

국문 초록
영문 초록
Purpose Thyroglobulin (Tg) is a biologic marker of differentiated thyroid carcinoma (DTC), produced by normal thyroid tissue or thyroid cancer tissue. Therefore, the Tg values of DTC patients is the most specific indicator for judging whether recurrence occur or whether the remaining thyroid cancer is present. Thyroid cancer is currently the most common cancer in Korea, of which 90% is differentiated thyroid cancer. The number of patients with thyroid disease of this application also increased, and an accurate and prompt results are required. However, the incubation time of the Tg commonly takes about 24 hours in our hospital, and the result reporting time is delayed, and We could not satisfied with the requirements of clinical departments and patients. In order to fulfill these requirements, experiments were conducted by shortening the incubation time between company B’s Kit currently in use and company C’s Kit used in other hospitals. Through these experiments, we could perform the correlation with the original method and shortening method, and could find the optimum reaction time to satisfy the needs of the departments and the patients, and we will improve the competitiveness with the EIA examination. Materials and Methods In September 2016, we tested 65 patients company B's kit and company C's kit by three incubation ways. First method 37℃ shaking 2hr/2hr, Second method RT shaking 3hr/2hr, Third method 1hr/1hr shaking at 37℃. Fourth method RT shaking 3hr method which is the original method of Company C's Kit. Fifth method, the incubation time was shortened under room temperature shaking 2hr, Sixth method 37℃ shaking 2hr. And we performed and compared the correlation and coefficient of each methods. Results As a result of performing shortening method on company B currently in use, when comparing the Original method of company B kit, First method 37℃ shaking 2hr/2hr was less than Tg 1.0 ng/mL and the ratio of R²=0.5906, above 1.0 ng/mL In the value, R²=0.9597. Second method RT shaking 3hr/2hr was R²=0.7262 less than value of 1.0 ng/mL, R²=0.9566 above than value of 1.0 ng/mL. Third method 37℃ shaking 1hr/1hr was R²=0.7728 less than value of 1.0 ng/mL, R²=0.8904 above than value of 1.0 ng/mL. Forth, Company C’s The original method, RT shaking 3hr was R²=0.7542 less than value of 1.0 ng/mL, and R²=0.9711 above than value of 1.0 ng/mL. Fifth method RT shaking 2hr was R²=0.5477 less than value of 1.0 ng/mL, R²=0.9231 above than value of 1.0 ng/mL. Sixth method 37℃ shaking 2hr showed R²=0.2848 less than value of 1.0 ng/mL, R²=0.9028 above than value of 1.0 ng/mL. Conclusion Samples with both values of 1.0 ng/mL or higher in both of the six methods showed relatively high correlation, but the correlation was relatively low less than value of 1.0 ng/mL. Especially, the 37℃ shaking 2hr method of company C showed a sharp fluctuation from the low concentration value of 1.0 ng/mL or less. Therefore, we are planning to continuously test the time, equipment, incubation temperature and so on for the room temperature shaking 2hr method and 37℃ shaking 1hr/1hr of company C which showed a relatively high correlation. After that, we can search for an appropriate shortening method through additional experiments such as recovery test, dilution test, sensitivity test, and provide more accurate and prompt results to the department of medical treatment, It is competitive with EIA test.
목차
서론
대상 및 방법
결과
결론 및 고찰
요약
REFERENCES
해당간행물 수록 논문
- 설문조사를 바탕으로 부서 간 만족도 향상을 위한 개선 안
- Thyroglobulin 검사의 반응조건에 따른 결과 비교 분석
- 방사성 동위원소를 이용한 핵의학과 검사에서 병동 간호사의 방사선 피폭선량 평가
- 대한핵의학기술학회 투고 논문 분류
- 전신 뼈 스캔의 오류 감소를 위한 프로세스 구축과 적용 효과
- Westgard Multi-Rules의 효율적 적용과 조치사항의 개선
- Brain SPECT 검사 시 Dynamic Continuous Mode의 유용성 평가
- 물리적 보정된 핵의학 영상 평가
- PET-CT 검사 시 호흡 동조 시스템들의 유용성 평가
- Thyroglobulin 검사의 반응조건에 따른 결과 비교 분석
- ⁵⁷Co 밀봉선원의 노후도에 따른 균일도의 변동과 중첩사용에 관한 유용성 평가
- PET/CT 검사에서 Flow mode를 적용한 Respiratory Gating Method 촬영과 추가 Gating 촬영의 비교 및 유용성 평가
- 갑상선 섭취율 측정에서 선원의 길이와 부피 증가에 따른 영향
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 민간의료보험 해약 의향 영향 요인: 한국 의료 패널 2019년 2기 자료를 이용하여
- 방사선학과 학생 실습환경에 관한 연구: 실습실 내 미세먼지, 휘발성유기화합물 위해도를 중심으로
- 임상에서 사용되는 온장고 온도설정 및 한계점에 대한 고찰
의약학 > 방사선과학분야 NEW
- 추출 크로마토그래피를 이용한 55Fe와 59/63Ni의 화학분리 중 목적원소 및 방해원소 거동 특성 연구
- 진단참고 준위를 적용한 선량 변화에 따른 영상 품질의 변화 평가
- 호주 방사선 의료 전문가 면허제도 및 교육과정 고찰: 진단방사선사를 중심으로
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!
