동적신장검사에서 저선량을 사용한 신장검사의 재현성 평가

이용수 0

영문명
Evaluation on Reproducibility of Low-Dose Kidney Scan in Dynamic Kidney Scan
발행기관
대한핵의학기술학회
저자명
이재상(Jaesang Lee) 이규찬(Kyuchan Lee) 이승환(Seunghwan Lee) 배성복(Seongbok Bae) 박종엽(Jongyeop Park)
간행물 정보
『핵의학기술』Vol.20 No.1, 59~65쪽, 전체 7쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2016.05.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose Dynamic kidney scan is a typical imaging technique that visualizes kidney function. Reproducibility of dynamic kidney scans has been evaluated by comparing low-dose kidney scans with low-dose radiopharmaceutical and standard dynamic kidney scan. With this comparative study, if reproducibility is superb, the dynamic kidney scan method with reduced radioactivity to patients is to be utilized and radiation exposure to patient is to be reduced. Materials and Methods For gamma camera, Orbiter, SymbiaE (Siemens, Germany) was used. Among patients who had used 370 Mbq (10 mCi) from January of 2013 to February 2014 and other patients who had used 185 Mbq (5 mCi) from March of 2014 to July of 2015 with identical condition, 21 subjects using DTPA and 20 subjects using MAG₃, 41 subjects in total, had been selected as subjects for data. From renogram of the result image, frame of the peak point was selected. Then, region of interest of kidney and background had been selected and Kidney to Background Ratio has been calculated for comparison. Results In tests using DTPA, kidney to background ratio when using 370 Mbq was 5.67 ± 0.8 at average while it was 5.62±0.87 when using 185 Mbq, which didn’t show much difference. Also in the tests using MAG₃, kidney to background ratio when using 370 Mbq was 14.95±2.58 at average and 14.56 ± 2.02 in 185 Mbq, which neither showed much difference. In paired sample t-test, p-value was 0.566 in DTPA and 0.363 in MAG₃, which confirmed that there was no difference between the groups. Conclusion In identical patients, when dose was decreased from 370 Mbq to 185 Mbq, reproducibility of dynamic kidney scan was proven to be excellent. Low-dose Dynamic kidney scan can achieve results with fine reproducibility without improvement in performance of gamma camera and is expected to reduce radiation exposure to patient.

목차

서론
대상 및 방법
결과
고찰
결론
요약
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

이재상(Jaesang Lee),이규찬(Kyuchan Lee),이승환(Seunghwan Lee),배성복(Seongbok Bae),박종엽(Jongyeop Park). (2016).동적신장검사에서 저선량을 사용한 신장검사의 재현성 평가. 핵의학기술, 20 (1), 59-65

MLA

이재상(Jaesang Lee),이규찬(Kyuchan Lee),이승환(Seunghwan Lee),배성복(Seongbok Bae),박종엽(Jongyeop Park). "동적신장검사에서 저선량을 사용한 신장검사의 재현성 평가." 핵의학기술, 20.1(2016): 59-65

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제