본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

치밀형 유방에서 Molecular Breast Imaging 검사의 유용성에 관한 고찰

이용수 0

영문명
Study on the Usefulness about Molecular Breast Imaging In Dense Breast
발행기관
대한핵의학기술학회
저자명
백송이(Song Ee Baek) 강천구(Chun Goo Kang) 이한울(Han Wool Lee) 박민수(Min Soo Park) 최영숙(Young Sook Choi) 김재삼(Jae Sam Kim)
간행물 정보
『핵의학기술』Vol.20 No.1, 42~46쪽, 전체 5쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2016.05.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose Mammography is the most widely used scan for the early diagnosis since it is possible to observe the anatomy of the breast. however, The sensitivity is markedly reduced in high-risk patients with dense breast. Molecular Breast Imaging (MBI) sacn is possible to get the high resolution functional imaging, and This new neclear medicine technique get the more improved diagnostic information through It is useful for confirmation of tumor's location in dense breast. The purpose of this study is to evaluate the usefulness of MBI for tumor diagnosis in patients with dense breast. Materials and Methods We investigated 10 patients female breast cancer with dense breast type who had visited the hospital from September 1st to Octorber 10th, 2015. The patients underwent both MBI and Mammography. MBI (Discovery 750B; General Electric Healthcare, USA) scan was 99mTc-MIBI injected with 20 mCi on the opposite side of the arm with the lesions, after 20 minutes, gained bilateral breast CC (CranioCaudal), MLO (Medio Lateral Oblique) View. Mammography was also conducted in the same posture. MBI and Mammography images were compared to evaluate the sensitivity and specificity of each case utilizing both image and two images in blind tests. Results The results of the blind test for breast cancer showed that the sensitivity of Mammography, MBI scan was 63%, 89%, respectively, and that their specificity was 38%, 87%, respectively. Using both the Mammography and MBI scan was Sensitivity 92%, specificity 90%. Conclusion This research has found that, The tumor of dense tissue that can not easily distinguishable in Mammography is possible to more accurate diagnosis since It is easy to visually evaluation. But MBI sacn has difficulty imaging microcalcificatons, If used in conjunction with mammography it is thought to give provide more diagnostic information.

목차

서론
대상 및 방법
결과 및 임상적 특징
결론 및 고찰
요약
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

백송이(Song Ee Baek),강천구(Chun Goo Kang),이한울(Han Wool Lee),박민수(Min Soo Park),최영숙(Young Sook Choi),김재삼(Jae Sam Kim). (2016).치밀형 유방에서 Molecular Breast Imaging 검사의 유용성에 관한 고찰. 핵의학기술, 20 (1), 42-46

MLA

백송이(Song Ee Baek),강천구(Chun Goo Kang),이한울(Han Wool Lee),박민수(Min Soo Park),최영숙(Young Sook Choi),김재삼(Jae Sam Kim). "치밀형 유방에서 Molecular Breast Imaging 검사의 유용성에 관한 고찰." 핵의학기술, 20.1(2016): 42-46

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제