학술논문
모집단 분포를 이용한 핵의학 혈액검사의 통계적 품질관리의 유용성
이용수 0
- 영문명
- Availability of Statistical Quality Control of Nuclear Medicine Blood Test Using Population Distribution
- 발행기관
- 대한핵의학기술학회
- 저자명
- 천준홍(Jun Hong Cheon) 조은빛(Eun Bit Cho) 유선희(Seon Hee Yoo) 김년옥(Nyeon Ok Kim)
- 간행물 정보
- 『핵의학기술』Vol.20 No.1, 37~41쪽, 전체 5쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2016.05.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.
국문 초록
영문 초록
Purpose The importance of quality control by the error to a minimum, which for the purpose of enhancing the reliability of the examination is not be emphasized excess. Currently, most nuclear medicine laboratory are conducting the internal and external quality control, and they are applying the Levey-Jennings or Westgard Multi-Rules by using the commercialized quality control materials. The reliability of the nuclear medicine blood test which affects the diagnosis of patients and the treatment policy is being secured through this quality control activity. Therefore, researchers will evaluate the utility of the statistic quality control using the population distribution of the nuclear medicine blood test conducted targeting the checkup examinees by the additional technique of the reliability improvement. Materials and Methods A statistic analysis was performed about 12 items of the nuclear medicine blood test targeting 41,341 peoples who used the health screening and promotion center in Asan Medical Center from January, 2014 to December, 2014. The results of 12 items of the nuclear medicine blood test was divided into the monthly percentage of three groups: within reference values, over reference, and under reference to analyze the average value of the population distribution, standard deviation, and standard deviation index (SDI). Results The standard deviation of the population distribution mostly showed a result within ±2SD in all groups. However, When the standard deviation of the population distribution represented a result over ±2SD, it was confirmed SDI was showing a result of SDI > -2 or SDI > 2. As a result of analyzing the population distribution of 12 items(AFP, CEA, CA19-9, CA125, PSA, TSH, FT4, Anti-Tg-Ab, Anti-TPO-Ab, Calcitonin, 25-OH-VitD3, Insulin) of the nuclear medicine blood part basic test, when SDI of the monthly percentage which deviated from the reference values was over ±2.0, CA19-9 September was 2.2, Anti-Tg-Ab may was 2.2, Insulin January was 2.3, Insulin March was 2.4. It was confirmed these cases were attributed to the abnormality of the test reagent (maximum combination rate of isotope reagent declined) and the decline of the test response time. Conclusion The population distribution includes the entire attribute which becomes the study object. It is expected the statistic quality management using the population distribution which was conducted targeting the checkup examinees by dividing into three groups: within reference values, over reference, and under reference by means of this characteristics will be able to play a role of complementing the internal quality control program which is being carried out in the laboratory.
목차
서론
대상 및 방법
결과
고찰 및 결론
요약
REFERENCES
해당간행물 수록 논문
- 저용량 I-131 투여시 Apron 착용여부에 따른 차폐효과에 대한 고찰
- 게이트 심장 혈액풀 스캔에서 심실중격 각도에 따른 좌전사위상 변화에 대한 연구
- 모집단 분포를 이용한 핵의학 혈액검사의 통계적 품질관리의 유용성
- ¹³N-ammonia 심장 PET 검사에서 ECG gated scan의 유용성 평가
- 방광 팬텀 제작을 통한 충만여부에 따른 방광 주변 병변에 대한 영상 평가
- Radium-223 Dichloride의 외부 방사선량의 평가
- 치밀형 유방에서 Molecular Breast Imaging 검사의 유용성에 관한 고찰
- Article PET/CT 검사에서 추가 검사 시 수분섭취에 따른 ¹⁸F-FDG의 신장 섭취 감소에 대한 고찰
- PET/CT 검사에서 종양의 특성에 따른 체적 측정 방법 비교
- 동적신장검사에서 저선량을 사용한 신장검사의 재현성 평가
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 의료용 인공지능에 대한 동향 분석 및 방사선사 인식조사
- CT contrast 검사 시 중심 정맥관을 이용한 조영제 사용에 대한 연구
- CT조영제 부작용 고위험군에 대한 전처치의 유용성
의약학 > 방사선과학분야 NEW
- 초음파 조직검사에 사용되는 Biopsy Gun Needle의 재질에 따른 반사율 연구
- 방사선에 대한 지식 및 인식도 연구
- 입원환자 일반촬영 이용량 및 피폭선량: 2018년 입원환자데이터
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!