학술논문
Ultrasensitive serum thyroglobulin의 유용성 평가
이용수 0
- 영문명
- Ultrasensitive serum thyroglobulin the usefulness of evaluation
- 발행기관
- 대한핵의학기술학회
- 저자명
- 이선호(Sun Ho Lee) 조은빛(Eun Bit Cho) 신영균(Young Kyun Shin) 이영지(Young Ji Lee) 유선희(Seun Hee Yoo) 김년옥(Nyun Ok Kim)
- 간행물 정보
- 『핵의학기술』Vol.19 No.2, 102~107쪽, 전체 6쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2015.10.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.
국문 초록
영문 초록
Purpose Serum Thyroglobulin measurement is a major tool for the follow-up of differentiated thyroid cancer (DTC) patients. Thyroglobulin is Normal thyroid tissue, or thyroid cancer tissue produced only. Thyroid hormone to a halt without Tg differentiation of thyroid cancer recurrence just by measuring how to decide whether there was increasing expectations if I can do it instead. Therefore, in excellent sensitivity Tg new inspection of the functional sensitivity by measuring the looked to evaluate the usefulness of reagents. Thyroidectomy is measuring the numbers Tg (total thyroidectomy) remaining thyroid ablation and radioactive iodine (radioactive iodine remnant ablation, RRA) DTC in patients being diagnosed with or help predict the remaining early detection of thyroid cancer recurrence. Materials and Methods Agent that I'm currently using Tg of the measurements of low clinical specimen for a second drainage of the three (0.08 0.17, 0.98, ng/mL) within the scope of the dilute magnification (2, 4, 8, 16, 32 times) by dilute Intraassy (n=10) and Interassay (n=10) out in no time. Concentration value according to the coefficient of variation and the mean and standard deviation of each measurement (Coefficient of variation, CV) the absolute value of the measured values that corresponds to 20 percent target a coefficient of variation of CV Find the value of the concentration of the functional sensitivity measurement did. Also, analytical sensitivity with recovery rates, Dilution test inspections, and interrelationship, compared. Results Sensitivity is an excellent analytical sensitivity within the prosecutor kit Tg 0.006 ng/mL, and core analytical sensitivity, conducted by the 0.006 ng/mL to same conclusion. Be rather high to 142 percent recovery rate was 60 to measurement and functional sensitivity, 0.01766 ng/mL(Intraassay n=10) was measured at. CBC is relatively good correlation as (R²=0.949) the correlation. Conclusion Recently ultrasensitive thyroglobulin this clinically important indicators of the previous kit and demands are lower than sensitivity to the measurement results. Therefore, ultrasensitive thyroglobulin test is correlated that there would be useful in value in nuclear medicine the thyroid gland.
목차
서론
실험재료 및 방법
결과
고찰
결론
참고문헌
해당간행물 수록 논문
- Ultrasensitive serum thyroglobulin의 유용성 평가
- Breast lymphoscintigraphy 검사 시 체표윤곽을 나타내는 방법의 비교
- PET/CT 검사 시 CT 피폭선량 감소 방법들의 최적화 평가
- Brain PET에서 Truncated Region에 의한 영상의 질 평가
- 장비정도관리에 Calibrator[I-125] Set 적용
- 심근 관류 SPECT에서 핵종에 따른 Uniformity correction map 설정을 통한 영상의 질 비교
- SPECT/CT 영상에서 에너지창 기반 산란보정과 CT 기반 산란보정 방법의 정량적 정확성 비교
- 25 Vitamin D3 측정에 있어서 화학발광미세입자 측정법과 화학발광면역 측정법 간의 비교 및 고찰
- PET-CT 검사 시 호흡동조 시스템을 이용한 인공물 감소에 대한 비교 평가
- 동적 타액선 신티그라피에서 기능적 매개변수 지표를 활용한 정량 분석의 유용성
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 의료용 인공지능에 대한 동향 분석 및 방사선사 인식조사
- CT contrast 검사 시 중심 정맥관을 이용한 조영제 사용에 대한 연구
- CT조영제 부작용 고위험군에 대한 전처치의 유용성
의약학 > 방사선과학분야 NEW
- 초음파 조직검사에 사용되는 Biopsy Gun Needle의 재질에 따른 반사율 연구
- 방사선에 대한 지식 및 인식도 연구
- 입원환자 일반촬영 이용량 및 피폭선량: 2018년 입원환자데이터
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!