학술논문
Breast lymphoscintigraphy 검사 시 체표윤곽을 나타내는 방법의 비교
이용수 0
- 영문명
- The comparison of lesion localization methods in breast lymphoscintigraphy
- 발행기관
- 대한핵의학기술학회
- 저자명
- 연준호(Joon ho Yeon) 홍건철(Gun chul Hong) 김수영(Soo yung Kim) 최성욱(Sung wook Choi)
- 간행물 정보
- 『핵의학기술』Vol.19 No.2, 74~80쪽, 전체 7쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2015.10.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.
국문 초록
영문 초록
Purpose Breast lymphoscintigraphy is an important technique to present for body surface precisely, which shows a lymph node metastasis of malignant tumors at an early stage and is performed before and after surgery in patients with breast cancer. In this study, we evaluated several methods of body outline imaging to present exact location of lesions, as well as compared respective exposure doses. Materials and Methods RANDO phantom and SYMBIA T-16 were used for obtaining imaging. A lesion and an injection site were created by inserting a point source of 0.11 M㏃ on the axillary sentinel lymph node and 37 M㏃ on the right breast, respectively. The first method for acquiring the image was used by drawing the body surface of phantom for 30 sec using Na ⁹⁹ᵐTcO₄ as a point source. The second, the image was acquired with ⁵⁷Co flood source for 30 seconds on the rear side and the left side of the phantom, the image as the third method was obtained using a syringe filled with 37 M㏃ of Na ⁹⁹ᵐTcO₄ in 10 ㎖ of saline, and as the fourth, we used a photon energy and scatter energy of ⁹⁹ᵐTc emitting from phantom without any addition radiation exposure. Finally, the image was fused the scout image and the basal image of SPECT/CT using MATLAB® program. Anterior and lateral images were acquired for 3 min, and radiation exposure was measured by the personal exposure dosimeter. We conducted preference of 10 images from nuclear medicine doctors by the survey. Results TBR values of anterior and right image in the first to fifth method were 334.9 and 117.2 (1st), 266.1 and 124.4 (2nd), 117.4 and 99.6 (3ʳᵈ), 3.2 and 7.6 (4ᵗʰ), and 565.6 and 141.8 (5ᵗʰ). And also exposure doses of these method were 2, 2, 2, 0, and 30 μ㏜, respectively. Among five methods, the fifth method showed the highest TBR value as well as exposure dose, where as the fourth method showed the lowest TBR value and exposure dose. As a result, the last method (5ᵗʰ)is the best method and the fourth method is the worst method in this study. Conclusion Scout method of SPECT/CT can be useful that provides the best values of TBR and the best score of survey result. Even though personal exposure dose when patients take scout of SPECT/CT was higher than another scan, it was slight level comparison to 1 m㏜ as the dose limit to non-radiation workers. If the scout is possible to less than 80 kV, exposure dose can be reduced, and also useful lesion localization provided.
목차
서론
실험 재료 및 방법
결과
결론
요약
참고문헌
해당간행물 수록 논문
- Ultrasensitive serum thyroglobulin의 유용성 평가
- Breast lymphoscintigraphy 검사 시 체표윤곽을 나타내는 방법의 비교
- PET/CT 검사 시 CT 피폭선량 감소 방법들의 최적화 평가
- Brain PET에서 Truncated Region에 의한 영상의 질 평가
- 장비정도관리에 Calibrator[I-125] Set 적용
- 심근 관류 SPECT에서 핵종에 따른 Uniformity correction map 설정을 통한 영상의 질 비교
- SPECT/CT 영상에서 에너지창 기반 산란보정과 CT 기반 산란보정 방법의 정량적 정확성 비교
- 25 Vitamin D3 측정에 있어서 화학발광미세입자 측정법과 화학발광면역 측정법 간의 비교 및 고찰
- PET-CT 검사 시 호흡동조 시스템을 이용한 인공물 감소에 대한 비교 평가
- 동적 타액선 신티그라피에서 기능적 매개변수 지표를 활용한 정량 분석의 유용성
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 의료용 인공지능에 대한 동향 분석 및 방사선사 인식조사
- CT contrast 검사 시 중심 정맥관을 이용한 조영제 사용에 대한 연구
- CT조영제 부작용 고위험군에 대한 전처치의 유용성
의약학 > 방사선과학분야 NEW
- 초음파 조직검사에 사용되는 Biopsy Gun Needle의 재질에 따른 반사율 연구
- 방사선에 대한 지식 및 인식도 연구
- 입원환자 일반촬영 이용량 및 피폭선량: 2018년 입원환자데이터
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!