The use of precontoured plates for midshaft clavicle fractures is not always the best course of treatment

이용수 0

영문명
The use of precontoured plates for midshaft clavicle fractures is not always the best course of treatment
발행기관
대한해부학회
저자명
Manmohan Patel Mohtashim Ahmad Natwar Agrawal Sumit Tulshidas Patil John Ashutosh Santoshi Bertha Rathinam Kusum Rajendra Gandhi
간행물 정보
『Anatomy and Cell Biology』Vol.56(4), 456~462쪽, 전체 7쪽
주제분류
의약학 > 의학일반
파일형태
PDF
발행일자
2023.12.31
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Plate fixation has become the preferred approach for treating displaced midshaft clavicle fractures. However, plate fixation of the clavicle presents several unique challenges, including its complex bony architecture and its immediate subcutaneous location. In many cases, we have observed that precontoured implants do not conform to the clavicular anatomy, and many patients complain of postoperative implant-related discomfort. A total of 111 clavicles, both left and right sides, were examined to match two commonly used designs of anatomical pre-contoured superior anterior clavicle plates, with and without lateral extension. The anteroposterior (AP) plane congruence of the plate to the underlying bone, the vertical gap between the bone and plate, and the length of the plate that was off the bone either anteriorly and/or posteriorly at both ends of the clavicle were measured. The scoring system was used to determine the fit of the implant on the clavicle as anatomic, good, or poor. We found that the maximum superior bow of the clavicle was lateral to the midline by 30.75 mm and 30.5 mm on the right and left sides, respectively. The magnitude of the bow was 4.28 mm and 4.46 mm on the right and left sides, respectively. We also found that the plate was a poor fit in 75.86% of cases on the left side and 73.5% of cases on the right side. Manipulating the plates during surgery was very difficult in the AP plane.

목차

Introduction
Materials and Methods
Results
Discussion
ORCID
Author Contributions
Conflicts of Interest
Funding
References

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

Manmohan Patel,Mohtashim Ahmad,Natwar Agrawal,Sumit Tulshidas Patil,John Ashutosh Santoshi,Bertha Rathinam,Kusum Rajendra Gandhi. (2023).The use of precontoured plates for midshaft clavicle fractures is not always the best course of treatment. Anatomy and Cell Biology, 56 (4), 456-462

MLA

Manmohan Patel,Mohtashim Ahmad,Natwar Agrawal,Sumit Tulshidas Patil,John Ashutosh Santoshi,Bertha Rathinam,Kusum Rajendra Gandhi. "The use of precontoured plates for midshaft clavicle fractures is not always the best course of treatment." Anatomy and Cell Biology, 56.4(2023): 456-462

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제