본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

Effect and Safety of Pressure Sensor-equipped Handpiece in Phacoemulsification System

이용수 0

영문명
Effect and Safety of Pressure Sensor-equipped Handpiece in Phacoemulsification System
발행기관
대한안과학회
저자명
Jin Yeong Kim Harin Kim Ikhyun Jun Tae-Im Kim Kyoung Yul Seo
간행물 정보
『The Korean Journal of Ophthalmology』Vol.37 No.5, 387~394쪽, 전체 8쪽
주제분류
의약학 > 의학일반
파일형태
PDF
발행일자
2023.10.31
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: To evaluate the effect of the Active Sentry handpiece of the Centurion Vision System compared to the Centurion Ozil handpiece for phacoemulsification in cataract surgery. Methods: A retrospective study was conducted on 281 patients (449 eyes) who underwent cataract surgery between August 2020 and June 2021. Preoperative measurements, intraoperative parameters, complication rate, and postoperative outcomes were compared between the Active Sentry handpiece and the Centurion Ozil handpiece groups. Additionally, the parameters were compared in different cataract severity groups and multiple predictive factors for the number of active surge mitigation (ASM) actuations were assessed with the Active Sentry handpiece. Results: There were 198 eyes in the Active Sentry group and 251 eyes in the Centurion Ozil group. There were no statistically significant differences between the two groups, as the cumulative dissipated energy in the Active Sentry and Centurion Ozil groups were 8.32 ± 7.74 and 7.87 ± 9.25 μJ, respectively (p = 0.576). Total surgery time, ultrasound usage time, aspiration time, amount of fluid aspirated, postoperative corrected distant visual acuity, and postoperative decrease in corneal endothelial cell density were comparable between the two groups. The significant contributors to the number of ASM actuations were age, preoperative corrected distant visual acuity, axial length, and total ultrasound time. Conclusions: There was no clear advantage of the Active Sentry handpiece compared to the Centurion Ozil handpiece. ASM actuation increases with age, poor visual acuity before surgery, short axial length, and prolonged ultrasound usage time. It is expected that in more severe and high-risk cataract surgery, the Active Sentry handpiece functions more effectively, possibly affecting the safety and prognosis.

목차

Materials and Methods
Results
Discussion
Supplementary Materials
References

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

Jin Yeong Kim,Harin Kim,Ikhyun Jun,Tae-Im Kim,Kyoung Yul Seo. (2023).Effect and Safety of Pressure Sensor-equipped Handpiece in Phacoemulsification System. The Korean Journal of Ophthalmology, 37 (5), 387-394

MLA

Jin Yeong Kim,Harin Kim,Ikhyun Jun,Tae-Im Kim,Kyoung Yul Seo. "Effect and Safety of Pressure Sensor-equipped Handpiece in Phacoemulsification System." The Korean Journal of Ophthalmology, 37.5(2023): 387-394

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제