Experimental Assessment of the Performance of Dual Pneumatic Vitreous Cutters According to Gauge and Cut Rate

이용수 0

영문명
Experimental Assessment of the Performance of Dual Pneumatic Vitreous Cutters According to Gauge and Cut Rate
발행기관
대한안과학회
저자명
Sooyeon Lee Kyung Seek Choi
간행물 정보
『The Korean Journal of Ophthalmology』Vol.37 No.4, 307~313쪽, 전체 7쪽
주제분류
의약학 > 의학일반
파일형태
PDF
발행일자
2023.08.31
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: To compare and analyze the performance of dual pneumatic ultra-high-speed vitreous cutters based on their cut rates, vacuum levels, and diameters in terms of flow rate and cutting time. Methods: The Constellation Vision System was used to remove egg white for 30 seconds, after which we calculated the flow rate by measuring the change in weight. We then measured the time required to remove 4 mL of egg white. We tested the UltraVit (UV) 7,500 cuts per minute (cpm) probe and the Advanced UltraVit (AUV) 10,000 cpm probe in biased open duty cycle mode, using 23-, 25-, and 27-gauge probes, respectively. Results: In biased open duty cycle, the flow rate tended to decrease as the cut rates increased for all three gauges. At the same cut rates, the flow rate increased as the vacuum level increased (p < 0.05), and as the diameter increased (p < 0.05). Among cutters with the same diameter, the AUV cutter showed higher flow rates than the UV cutter, with increases of 0.267 mL/ min (18.5%) at 27 gauge, 0.627 mL/min (20.8%) at 25 gauge, and 1.000 mL/min (20.7%) at 23 gauge (all p < 0.05). The times required to remove 4 mL of egg white took longer with the UV cutter than the AUV cutter for all three gauges (all p < 0.05). Conclusions: The use of a smaller gauge vitreous cutter may reduce the flow rate and increase the time required for vitrectomy, but this can be partially compensated for by increasing the vacuum level as well as using a vitreous cutter with a higher maximum cut rate, improved port size, and improved duty cycle.

목차

Materials and Methods
Results
Discussion
References

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

Sooyeon Lee,Kyung Seek Choi. (2023).Experimental Assessment of the Performance of Dual Pneumatic Vitreous Cutters According to Gauge and Cut Rate. The Korean Journal of Ophthalmology, 37 (4), 307-313

MLA

Sooyeon Lee,Kyung Seek Choi. "Experimental Assessment of the Performance of Dual Pneumatic Vitreous Cutters According to Gauge and Cut Rate." The Korean Journal of Ophthalmology, 37.4(2023): 307-313

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제