본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

저장 및 분석중 도금공정 Cr(VI) 시료의 환원에 관한 연구

이용수 6

영문명
Reduction of Hexavalent Chromium Collected on PVC Filter from Electroplating Process during Storage and Analysis
발행기관
한국환경보건학회
저자명
신용철(Yong Chul Shin) 백남원(Nam Won Paik)
간행물 정보
『1. 한국환경보건학회지』제25권 제2호, 8~17쪽, 전체 10쪽
주제분류
공학 > 환경공학
파일형태
PDF
발행일자
1999.06.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

It is known that hexavalent chromium (Cr(VI)) is unstable and can be reduced to a lower valence in air. Therefore, reduction of Cr(VI) in the steps of sampling, storage and analysis will result in underestimation of Cr(VI) level. The purpose of the study is to suggest some appropriate procedures for minimizing the reduction of Cr(VI) during storage and analysis of the air samples collected on PVC filters from pilot electroplating process, and of samples spiked with a plating bath solution from a factory. The average ratio of Cr(VI) recoveries by acid extraction (0.5N H₂SO₄) to those by alkali extraction (2% NaOH/3% Na₂CO₃) in spiked samples was 0.83 ± 0.06. These data indicate that acid extraction can cause the Cr(VI) to be reduced, and Cr(VI) samples on PVC filters should be leached with an alkali solution to prevent from the reduction. Storage time was a significant factor effecting Cr(VI) reduction in samples stored (in vials) at room temperature. The recoveries of Cr(VI) in air samples stored in vial at room temperature were 74% after 1 day, and 56-57% after 3-7 days. The recoveries in spiked samples at the similar condition were 77% after 4 days, 75% after 8 days, and 72% after 17 days. The recovery of Cr(VI) was improved in the air samples by storing them at 4°C (87% after 1 day and 74-83% after 3-7 days). In addition, recovery from the spiked samples stored in vials at 4 °C was higher those stored at room temperature. Thus, it is required that filter sample be stored at 4°C or lower. Storage time was not a significant factor when the Cr(VI) samples were stored in either a 2% NaOH/3% Na₂CO₃ or 0.02M NaHCO₃ solution. Thus, we recommend that Cr(VI) samples from a plating process be stored in a alkali solution to prevent further reduction. In conclusion, this study demonstrates that acid extraction and storage time can lead to a loss of Cr(VI) on PVC filter samples through reduction. These losses will result in an underestimation of Cr(VI) exposure/concentration. we also found that these losses can be minimized by using alkali extraction, by refrigerating the samples during the interim between sample collection and analysis, by minimizing the storage time, and by storing the samples in an alkali solution.

목차

I. 서론
II. 재료 및 방법
III. 연구결과
IV. 고찰
V. 결론

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

신용철(Yong Chul Shin),백남원(Nam Won Paik). (1999).저장 및 분석중 도금공정 Cr(VI) 시료의 환원에 관한 연구. 1. 한국환경보건학회지, 25 (2), 8-17

MLA

신용철(Yong Chul Shin),백남원(Nam Won Paik). "저장 및 분석중 도금공정 Cr(VI) 시료의 환원에 관한 연구." 1. 한국환경보건학회지, 25.2(1999): 8-17

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제