본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

Refractive Predictability of Partial Coherence Interferometry and Factors that can Affect It

이용수 0

영문명
발행기관
대한안과학회
저자명
Seung Mo Kim Joohyun Choi Sangkyung Choi
간행물 정보
『The Korean Journal of Ophthalmology』Vol.23 No.1, 6~12쪽, 전체 7쪽
주제분류
의약학 > 기타의약학
파일형태
PDF
발행일자
2009.03.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: To evaluate the refractive predictability of a partial coherence interferometry (PCI) biometry device (IOL Master??) for cataract surgery and to investigate factors that may affect it. Methods: Retrospective review of 209 eyes from 151 patients that had undergone preoperative PCI biometry and an uneventful phacoemulsification cataract surgery with posterior chamber intraocular lens (IOL) implantation was conducted. Prediction error defined as the intended refraction minus the postoperative refraction in spherical equivalent (SE) and the absolute error were analyzed according to IOL calculation formulas, patient characteristics, preoperative visual acuity (VA) and refraction, posterior subcapsular cataract (PSC), signal-to-noise ratio (SNR), and axial length (AL). Results: The overall refractive predictability of the PCI device was good. Generally, the SRK/T formula performed better than the SRK-II formula. Refractive predictability was slightly worse in eyes with ≥+2.0 diopters (D) of preoperative SE (with both SRK-II and SRK/T) and in eyes with an AL≤23.0 mm (only with SRK-II. No other factors significantly affected the refractive predictability of the PCI, although poor VA, dense PSC, and poor SNR were closely interrelated. Conclusions: The SRK/T formula performed significantly better than the SRK-II formula. Eyes with an AL≤23.0 mm were associated with significantly greater hyperopic shifts in postoperative refraction with the SRK-II formula, but not with the SRK/T formula. A preoperative SE≥+2.0D was related to a significantly greater hyperopic shift in postoperative refraction. With proper verification of measured data and a suitable IOL calculation formula, good refractive predictability is expected from PCI biometry regardless of patient characteristics, preoperative VA, SNR, PSC, and AL. Korean J Ophthalmol 2009;23:6-12 ⓒ 2009 by the Korean Ophthalmological Society.

목차

Materials and Methods
Discussion
References

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

Seung Mo Kim,Joohyun Choi,Sangkyung Choi. (2009).Refractive Predictability of Partial Coherence Interferometry and Factors that can Affect It. The Korean Journal of Ophthalmology, 23 (1), 6-12

MLA

Seung Mo Kim,Joohyun Choi,Sangkyung Choi. "Refractive Predictability of Partial Coherence Interferometry and Factors that can Affect It." The Korean Journal of Ophthalmology, 23.1(2009): 6-12

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제