Comparison Between Dynamic Contour Tonometry and Goldmann Applanation Tonometry

이용수 0

영문명
발행기관
대한안과학회
저자명
Jooeun Lee Chang Hwan Lee Jaewan Choi Sam Young Yoon Kyung Rim Sung Seong Bae Park Michael S. Kook
간행물 정보
『The Korean Journal of Ophthalmology』Vol.23 No.1, 27~31쪽, 전체 5쪽
주제분류
의약학 > 기타의약학
파일형태
PDF
발행일자
2009.03.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: To compare the intraocular pressures (IOPs) measured by dynamic contour tonometry (DCT) and Goldmann applanation tonometry (GAT), and to investigate the association of IOPs on eyes of varying central corneal thickness (CCT). Methods: In this prospective study, 451 eyes of 233 subjects were enrolled. IOPs were measured by GAT and DCT. CCT was measured three times and the average was calculated. Each eye was classified into one of three groups according to CCT: low CCT (group A, CCT<520 μm, n=146); normal CCT (group B, 520 μm≤CT≤550 μm, n=163); and high CCT (group C, CCT>550 μm, n=142). In each group, we investigated the association of CCT with IOP measurement by GAT and DCT. Results: The IOPs measured by GAT and DCT were significantly associated for all eyes (R=0.853, p<0.001, Pearson correlation). CCT was related with both IOP measurement by GAT and DCT with statistical significance (mixed effect model, p<0.001). However, subgroup analysis showed that CCT affected IOP measured by GAT for groups B and C, whereas it affected IOP measured by DCT only for group C. Conclusions: IOP measured by DCT was not affected by CCT in eyes with low to normal CCT, whereas this measurement was affected in eyes of high CCT range. CCT may have less effect on IOP measurements using DCT than those obtained by GAT, within a specified range of CCT.

목차

Materials and Methods
Results
Discussion
References

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

Jooeun Lee,Chang Hwan Lee,Jaewan Choi,Sam Young Yoon,Kyung Rim Sung,Seong Bae Park,Michael S. Kook. (2009).Comparison Between Dynamic Contour Tonometry and Goldmann Applanation Tonometry. The Korean Journal of Ophthalmology, 23 (1), 27-31

MLA

Jooeun Lee,Chang Hwan Lee,Jaewan Choi,Sam Young Yoon,Kyung Rim Sung,Seong Bae Park,Michael S. Kook. "Comparison Between Dynamic Contour Tonometry and Goldmann Applanation Tonometry." The Korean Journal of Ophthalmology, 23.1(2009): 27-31

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제