소아 CT검사시 적정 노출조건 설정에 관한 연구

이용수 13

영문명
The choice of optimal X-ray exposure factors in pediatric body CT
발행기관
대한CT영상기술학회
저자명
신상보(Sang Bo Shin) 신설경(Sul Kyung Shin) 이대규(Dae Kyoo Lee) 김문찬(Moon Chan Kim)
간행물 정보
『대한CT영상기술학회지』대한전산화단층기술학회지 제9권 제1호, 55~61쪽, 전체 7쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2007.04.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose The increased radiation sensitivity of children causes them to have an age-dependent radiation risk that is 2-3 times larger than that of the general population. For this reason, the purpose of this study is selection of optimal x-ray exposure factors in pediatric CT. The absolute values for radiation exposure in CT depend strongly on the scan parameters, scanner characteristics, and the patients. Materials and Methods There are separate data provided for body applications(measured in a 32cm PMMA phantom) or head scans(16cm PMMA phantom). CTDI measurements are made at various positions within a body or head PMMA phantom. Measurements of the CTDI are performed in the center and 1cm below the surface of a cylindrical plexiglas phantom of 32cm diameter for the bodyand 16cm for the head. In a larger patient more is absorbed in the periphery so that the local dose in the center is less than it would be for a slimmer patient. Dose to the periphery also decreases for larger patients. Results CTDIw decreases with larger phantom diameters, which implies that the real average dose is underestimated for children and slim patients. Radiation induced risk in children can be substantially higher than the risk in the adult population. For this reason, the radiologist should double-check the indication for CT, and should adapt the radiation dose to the body cross-section. Longitudinal and adaptive dose modulation would be ideal technique, but presently only rough suggestion based on the body weight are available. One have to keep in mind, however, that the body weight may underestimate the dose requirements in obese children because their body cress-section can be larger than that of a taller child of identical weight. Tube current modulation takes advantage of the fact that there is a substantial difference in radiation attenuation of a body. Conclusion The best choice is adapts dose modulation at pediatric CT. This will be important step towards more constant image quality and dose reduction in CT.

목차

Abstract
Ⅰ. 목적
Ⅱ. 대상 및 방법
Ⅲ. 결과
Ⅳ. 고찰
Ⅴ. 결론
참고문헌

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

신상보(Sang Bo Shin),신설경(Sul Kyung Shin),이대규(Dae Kyoo Lee),김문찬(Moon Chan Kim). (2007).소아 CT검사시 적정 노출조건 설정에 관한 연구. 대한CT영상기술학회지, 9 (1), 55-61

MLA

신상보(Sang Bo Shin),신설경(Sul Kyung Shin),이대규(Dae Kyoo Lee),김문찬(Moon Chan Kim). "소아 CT검사시 적정 노출조건 설정에 관한 연구." 대한CT영상기술학회지, 9.1(2007): 55-61

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제