본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

Liver Volumetry에 있어 Graphic Tablet System과 Mouse System의 유용성 비교에 관한 연구

이용수 10

영문명
Graphic Tablet System and Mouse System’s Usefulness Comparison in Liver Volumetry
발행기관
대한CT영상기술학회
저자명
박성모(Sung Mo Park) 부재철(Jae Cheol Boo) 이현진(Hyun Jin Lee) 김순배(Soon Bae Kim) 김경수(Kyung Soo Kim)
간행물 정보
『대한CT영상기술학회지』대한전산화단층기술학회지 제9권 제1호, 27~31쪽, 전체 5쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2007.04.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose Survival capacity of donor and recipient in liver transplantation is important item after the prognosis after operation. Wished to ready Graphic Tablet’s Usefulness and liver volume log standardization guide through correct liver volume relationship sounding. Materials and Methods From August, 2005 to February, 2007, did to 38 donor and recipients that conduct liver Transplantation Dynamic CT examination for living donor liver transplantation and man 23 woman 15 people age is 18 - 55 and was average age 35 years old. Measured reconstruction image using Graphic Tablet and Mouse in Rapidia 3.0 that is 3D Workstation by each 1.25mm, 2.5mm, 5mm, 10m mm Thickness from liver upper lobe to lower lobe. Capacity measurement method that go portal vein bifurcation discernment that increase in liver volume as possible except and divided liver left and right lobe via middle hepatic vein coming hepatic vein bifurcation. A Group measured 1.25mm, 2.5mm, 5mm, 10m mm relationship liver right lobe by Mouse. B Group measured 1.25mm, 2.5mm, 5mm, 10m mm relationship liver right lobe by Tablet. C Group analyzed A Group and B Group’s liver volume measured value and actuality liver volume course comparison. D Group analyzed efficiency about liver volume measurement time required and party different nature in user side. Found the most suiTable liver volume measurement Parameter analyzing error of actuality liver volume course after value and living donor liver transplantation as result that is measured by Mouse and Graphic Tablet before operation. Results Accuracy of Graphic Tablet appeared than Mouse high as result that use each Thickness different Mouse and Graphic Tablet and compare with actuality liver right lobe’s volume as result that measure liver right lobe. Accuracy of Thickness appeared in the widest 10mm low and Thickness decreases, accuracy was expose that rise. Accuracy roses but increased capital of reflex as Thickness that decrease decreased Thickness A and liver volume log time increased. Graphic Tablet appeared high than Mouse time required and accuracy side as result that analyze liver volume log efficiency. Conclusion Capacity measurement that go that use Graphic Tablet conclusively could heighten step that do believability about examination result and could shorten capacity measurement time required that go.

목차

Abstract
Ⅰ. 서론
Ⅱ. 대상 및 방법
Ⅲ. 결과
Ⅳ. 고찰 및 결론
참고문헌

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

박성모(Sung Mo Park),부재철(Jae Cheol Boo),이현진(Hyun Jin Lee),김순배(Soon Bae Kim),김경수(Kyung Soo Kim). (2007).Liver Volumetry에 있어 Graphic Tablet System과 Mouse System의 유용성 비교에 관한 연구. 대한CT영상기술학회지, 9 (1), 27-31

MLA

박성모(Sung Mo Park),부재철(Jae Cheol Boo),이현진(Hyun Jin Lee),김순배(Soon Bae Kim),김경수(Kyung Soo Kim). "Liver Volumetry에 있어 Graphic Tablet System과 Mouse System의 유용성 비교에 관한 연구." 대한CT영상기술학회지, 9.1(2007): 27-31

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제