본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

High Dose Computed Tomography검사의 Exposure Dose 측정 및 평가

이용수 0

영문명
Evaluation of High dose Computed Tomography in Exposure dose Study
발행기관
대한CT영상기술학회
저자명
김주(Joo Kim) 권성옥(Seong Ohk Kwon) 김기홍(Ki Hong Kim) 서동수(Dong Soo Suh) 최준호(Joon Ho Choi)
간행물 정보
『대한CT영상기술학회지』대한전산화단층기술학회지 제9권 제1호, 85~89쪽, 전체 5쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2007.04.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose Charge of patient decreased on account of National Health Insurance benefit in CT examination. Scan time is reduced by generalization of spinal CT and utility of MDCT technic. Accuracy of diagnosis has improved because of up-to-date software. As a result, coefficient of utilization on CT examination increased and exposure dose is reduced by improved performance of detector and CT unit. It was necessary to use Thin slice in other to acquire a quantity of data but radiation hazard of adapted Multi-phase study increased. This Study evaluates exposure dose in CT examination. Objects and Methods CT head arteriography protocol is 20kVp, 100~300mAs, tube rotation time 0.5 or 1sec, total scan time 53sec, neck arteriography protocol is 120kVp, 150~300mAs, tube rotation time 0.5, 0.75 or 1sec, total scan time 67sec. CT OMU protocol is 120kVp, 120mAs, tube rotation time 1sec, total scan time 30sec. CT perfusion protocol is 80kVp, 200mAs, tube rotation time 1sec, total scan time 40sec. CT coronary artery protocol is 120kVp, pre : 20mAs, coronary artery : 600mAs, tube rotation time 0.5, or 0.37sec, total scan time 32sec. CT 3D intestine protocol is 120kVp, 200mAs, tube rotation time 0.5sec, total scan time 88sec. We located Ionization chamber at the center brain and abdomen acrylic and measure exposure dose. Results Exposure dose of CT head arteriography is 12.6R, exposure dose of CT neck arteriography is 23.83R, exposure dose of CT OMU is 12.6R, exposure dose of CT coronary artery is 6.15R, exposure dose of CT 3D intestine is 9.68R. We measured 5 times multi-phase study of CT neck arteriography, CT 3D intestine : 5 times, CT OMU : 2 times, CT perfusion : 2 times, CT coronary artery : 3 times Conclusion Exposure dose of CT head arteriography is 12. 6R which is maximum value and exposure dose of CT OMU is 12.6R which is minimum value. there is not only benefit but also a loss

목차

Abstract
Ⅰ. 서론
Ⅱ. 대상 및 방법
Ⅲ. 결과
Ⅳ. 고찰
Ⅴ. 결론
참고문헌

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

김주(Joo Kim),권성옥(Seong Ohk Kwon),김기홍(Ki Hong Kim),서동수(Dong Soo Suh),최준호(Joon Ho Choi). (2007).High Dose Computed Tomography검사의 Exposure Dose 측정 및 평가. 대한CT영상기술학회지, 9 (1), 85-89

MLA

김주(Joo Kim),권성옥(Seong Ohk Kwon),김기홍(Ki Hong Kim),서동수(Dong Soo Suh),최준호(Joon Ho Choi). "High Dose Computed Tomography검사의 Exposure Dose 측정 및 평가." 대한CT영상기술학회지, 9.1(2007): 85-89

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제