Dual Source CT와 Multi Detector CT에서 Coronary 검사의 방사선량 분석

이용수 33

영문명
A Study on Radiation dose of Dual Source CT and Multi Detecter CT in Coronary study
발행기관
대한CT영상기술학회
저자명
권성옥(Seong Ohk Kwon) 하동윤(Dong Yoon Ha) 최준호(Joon Ho Choi) 이상우(Sang Woo Lee) 서동수(Dong Soo Suh)
간행물 정보
『대한CT영상기술학회지』대한전산화단층기술학회지 제9권 제1호, 41~46쪽, 전체 6쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2007.04.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose This study compared an exposure dose of DSCT with MDCT in cardiac CT and we analyzed how much the radiation dose increased or decreased. Materials and Methods For an experiment, CT device for the human body was used by 16 channel MDCT(Multi Detecter CT) manufactured by siemens and DSCT(Dual Source CT) called by SIEMENS Somatom Definition CT. It is available for supplying two source with each different kVp and mAs, processing and gathering the data at the same time. we used ECG Simulator(Marquette Electronics. USA) for examining a change of Heart Rate. An experiment method compares CTDIvol and CTDIDLP of DSCT with MDCT and is to measure. it was performed by using ECG Simulator in DSCT Coronary study, giving Heart Rate with a variety of numerical value, such as 50bpm, 55bpm, 60bpm, 65bpm, 70bpm, 75bpm, 80bpm, 85bpm, 90bpm, 95bpm, 100bpm, 105bpm, 110bpm, according to high or low of each heart rate, comparing and measuring CTDIvol and CTDIDLP, we can know whether there is some differences. Results 1. The Coronary study protocol of MDCT is 120kVp, 600mAs, Rotation time 0.37sec, Scan Time 18~20sec. CTDIvol and CTDIDLP measured each 46.80mGy, 936mGy. The Coronary study protocol of DSCT is 120kVp, 300mAs, Rotation time 0.33sec, Scan Time 8~10sec. CTDIvol and CTDIDLP measured each 47.45mGy, 427.05mGy. As a result, CTDIDLP was reduced about 55% in DSCT compared with Multi Detecter CT though CTDIvol is similar. 2. Heat rate of Coronary Study used ECG Simulator in DSCT is 50bpm, 55bpm, 60bpm, 65bpm, 70bpm, 75bpm, 80bpm, 85bpm, 90bpm, 95bpm, 100bpm, 105bpm, 110bpm. according to high or low of each heart rate, CTDIvol is measured to 60.81mGy in 50bpm and 29.llmGy in 110bpm. 3. CTDIvol and CTDIDLP of MDCT used Coronary study protocol is measured to 46.80mGy and 936mGy. measured CTDIvol of DSCT is 29.11~60.81mGy in 50bpm ~110bpm heart rate and CTDIDLP is measured to 261.99~547.29mGy. Conclusion The Dual Source CT is increased 29.9%~0.1% of CTDIvol in 50bpm ~ 110bpm compared with the Multi Detecter CT. And the CTDIvol in 70bpm ~ 110bpm was reduced by 9%~37.8. In the Single Source the Table speed came to be late as a heart rate increase. On the other hand, The Table speed of DSCT did fast according to the increase of the Heart Rate and The Scan time is reduced. When heart rate is slow, CTDIDLP of Dual Source CT is reduced by 41.6 % compared with Multi Detecter CT and When heart rate is fast, CTDim.P of Dual Source CT is reduced by 72.1% compared with Multi Detecter CT.

목차

Abstract
Ⅰ. 목적
Ⅱ. 대상 및 방법
Ⅲ. 결과
Ⅳ. 고찰
Ⅴ. 결론
참고문헌

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

권성옥(Seong Ohk Kwon),하동윤(Dong Yoon Ha),최준호(Joon Ho Choi),이상우(Sang Woo Lee),서동수(Dong Soo Suh). (2007).Dual Source CT와 Multi Detector CT에서 Coronary 검사의 방사선량 분석. 대한CT영상기술학회지, 9 (1), 41-46

MLA

권성옥(Seong Ohk Kwon),하동윤(Dong Yoon Ha),최준호(Joon Ho Choi),이상우(Sang Woo Lee),서동수(Dong Soo Suh). "Dual Source CT와 Multi Detector CT에서 Coronary 검사의 방사선량 분석." 대한CT영상기술학회지, 9.1(2007): 41-46

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제