본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

하악우각부 골절의 골내고정후 응력분포에 관한 3차원 유한요소법적 연구

이용수 0

영문명
The 3-d fem stress anaylsis of the internal fixation for the fracture of mandibular angle
발행기관
대한구강악안면외과학회
저자명
김용한(Yong Han Kim) 김명래(Myung Rae Kim) 최장우(Jang Woo Choi) 조규종(Gue Jong Joh)
간행물 정보
『대한구강악안면외과학회지』대한구강악안면외과학회지 제22권 제4호, 633~642쪽, 전체 10쪽
주제분류
의약학 > 내과학
파일형태
PDF
발행일자
1996.10.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

It has been considered that tension is developed onto the superior border(along the osteosynthesis line) and compression presents at the inferior border of the mandible when the occlusal load is applied at the two dimensional model of the fractured mandible. Therefore, the internal fixation with one miniplate on the external oblique ridge of the mandible insisted by Champy et ais. (1972) seemed to be adequate to stabilize the bone segments of the mandibular angle fractures. But many clinicians doubted that torque stress as well as compressive stress may be developed at the inferior border of 3-dimensional mandible during loading. Kroon et als(1991) reported that the torque stress must be controlled bv additional internal fixation to prevent torsion of the fraoments. This is an experimental design to study the stress distribution after the internal fixation with monocortical miniplates and additional devices. The 3-dimensional finite element measurement analysis was used with (1) one miniplate at the superior border(1MP), (2) two miniplates at the superior border and inferior border(2MP), and (3) one miniplate at the superior border and suspension wire-bridge at the inferior border(1MP-SW) The results are as following; (1) When the occlusal load is applied to the fractured posterior molar region, the stress distributions of 2MP and 1MP-SW are close to the unfractured model. (2) When the occlusal load is applied to fractured posterior molar region, the gap of displacement at the inferior border was more significant in 1MP than 2MP or 1MP-SW. (3) When the occlusal load is applied to un-fractured site, there are no differences in the stress distributions between 1MP, 2MP and 1MP-SW. (4) It can be concluded that the auxillary inferior suspension wiring is a good option in the management of mandibular angle fractures to resist the functional load and pevent the development of gap between the fractured segments.

목차

Abstract
I. 서론
II. 연구재료 및 연구방법
III. 연구성적
IV. 고찰
IV. 결론
참고문헌

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

김용한(Yong Han Kim),김명래(Myung Rae Kim),최장우(Jang Woo Choi),조규종(Gue Jong Joh). (1996).하악우각부 골절의 골내고정후 응력분포에 관한 3차원 유한요소법적 연구. 대한구강악안면외과학회지, 22 (4), 633-642

MLA

김용한(Yong Han Kim),김명래(Myung Rae Kim),최장우(Jang Woo Choi),조규종(Gue Jong Joh). "하악우각부 골절의 골내고정후 응력분포에 관한 3차원 유한요소법적 연구." 대한구강악안면외과학회지, 22.4(1996): 633-642

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제