본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

임플란트 식립 부위의 골밀도 평가에 관한 연구

이용수 16

영문명
The study of bone density assessment on dental implant sites
발행기관
대한구강악안면외과학회
저자명
박수원(Su-Won Park) 장수미(Soo-Mi Jang) 최병환(Byoung-Hwan Choi) 손한나(Han-Na Son) 박봉찬(Bong-chan Park) 김창환(Chang-Hwan Kim) 손장호(Jang-Ho Son) 성일용(Iel-Yong Sung) 이지호(Ji-Ho Lee) 조영철(Yeong-Cheol Cho)
간행물 정보
『대한구강악안면외과학회지』대한구강악안면외과학회지 제36권 제5호, 417~422쪽, 전체 6쪽
주제분류
의약학 > 내과학
파일형태
PDF
발행일자
2010.10.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Introduction: Bone density is one of the important factors for the long term success of endosseous implants. The bone density varies from site to site and from patient to patient. A preoperative evaluation of the bone density is quite useful to oral surgeons for planning dental implantation. More accurate information on the bone density will help surgeons identify suitable implant sites, thereby increase the success rate of dental implantation. This study examined the correlation between the bone density measured preoperatively by computed tomography (CT) and the implant primary stability measured by resonance frequency analysis. Furthermore, the effects of the implant sites, gender, age and generalized systemic disorder patients on the bone density and primary implant stability were examined. Materials and Methods: One hundred and fourteen patients were selected. None of the patients had undergone a tooth extraction or bone graft history in the previous year. Preoperatively, the patients underwent CT scanning to evaluate the Hounsfield unit (HU), and resonance frequency analysis(RFA) was used to evaluate the implant primary stability at the time of implant installation. All implants were 4.0 mm diameter and 11.5 mm length US II. All patients were recorded and the HU and implant stability quotient (ISQ) value were evaluated according to the sites, gender and age. Results: The highest HU values were found in the mandibular anterior site (827.6±151.4), followed by the mandibular molar site (797±135.1), mandibular premolar site (753.8±171.2), maxillary anterior site (726.3±154.4), maxillary premolar site (656.7±173.8) and maxillary molar site (621.5±164.9). The ISQ value was the highest in the mandibular premolar site (81.5±2.4) followed by the mandibular molar site (80.0±5.7), maxillary anterior site (77.4±4.1), mandibular anterior site (76.4±11.9), maxillary premolar site (74.2±14.3) and maxillary molar site (73.7±7.4). The mean HU and ISQ value were similar in females and males. (HU: P=0.331, ISQ: P=0.595) No significant difference was also found in the age group respectively. However, the correlation coefficients between the variables showed a closed correlation between the HU and ISQ value. Conclusion: These results showed close correlation between the bone density (HU) and primary stability value (ISQ) at the time of implant installation(Correlation coefficients=0.497, P<0.01). These results strengthen the hypothesis that it might be possible to predict and quantify the initial implant stability and bone density from a presurgical CT diagnosis.

목차

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

박수원(Su-Won Park),장수미(Soo-Mi Jang),최병환(Byoung-Hwan Choi),손한나(Han-Na Son),박봉찬(Bong-chan Park),김창환(Chang-Hwan Kim),손장호(Jang-Ho Son),성일용(Iel-Yong Sung),이지호(Ji-Ho Lee),조영철(Yeong-Cheol Cho). (2010).임플란트 식립 부위의 골밀도 평가에 관한 연구. 대한구강악안면외과학회지, 36 (5), 417-422

MLA

박수원(Su-Won Park),장수미(Soo-Mi Jang),최병환(Byoung-Hwan Choi),손한나(Han-Na Son),박봉찬(Bong-chan Park),김창환(Chang-Hwan Kim),손장호(Jang-Ho Son),성일용(Iel-Yong Sung),이지호(Ji-Ho Lee),조영철(Yeong-Cheol Cho). "임플란트 식립 부위의 골밀도 평가에 관한 연구." 대한구강악안면외과학회지, 36.5(2010): 417-422

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제