본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

생체계측치와 각막 곡률의 차이에 따른 인공수정체 삽입 후 굴절 오차의 경향

이용수 0

영문명
발행기관
대한안과학회
저자명
이강훈 김나래 서경률,Kang Hoon Lee, MD, Na Rae Kim, MD, Kyoung Yul Seo, MD, PhD
간행물 정보
『대한안과학회지』Ophthalmological Society,volume54,number9, 1345~1352쪽, 전체 8쪽
주제분류
의약학 > 기타의약학
파일형태
PDF
발행일자
2013.09.15
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: The purpose of this study was to investigate the error tendency between preoperative expected refraction and postoperative manifest refraction based on axial length, anterior chamber depth, and keratometric data obtained by an automated keratometer and Pentacam® in cataract surgery cases and to report how their differences affect determination of intraocular lens (IOL) power. Methods: The authors retrospectively reviewed the medical records of 110 eyes of 84 patients who underwent cataract surgery. Axial length and anterior chamber depth were measured by A scan ultrasound biometry, while keratometric values were obtained by an automated keratometer and Pentacam®. IOL power was calculated using the SRK/T formula. Patients were divided into 3 groups based on the axial length, anterior chamber depth, and the difference of keratometric values between the 2 devices. Refractive error was analyzed 2 months after surgery. Results: There were no statistically significant differences between axial length and anterior chamber depth among the groups; however, the K reading differences were statistically significant. Although the mean absolute error (MAE) of each group showed no statistical significance among the groups, the MAE was more pronounced in the group in which the keratometeric value measured by Pentacam® differed more than 1.00 diopter from the automated keratometer measurements. Conclusions: There was no statistically significant difference between axial length and anterior chamber depth among the groups. A difference of 1.00 diopter or more between the keratometric values obtained by an automated keratometer and Pentacam® significantly affects the postoperative refractive error; therefore, these factors should be considered when determining IOL power.

목차

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

이강훈,김나래,서경률,Kang Hoon Lee, MD, Na Rae Kim, MD, Kyoung Yul Seo, MD, PhD. (2013).생체계측치와 각막 곡률의 차이에 따른 인공수정체 삽입 후 굴절 오차의 경향. 대한안과학회지, 54 (9), 1345-1352

MLA

이강훈,김나래,서경률,Kang Hoon Lee, MD, Na Rae Kim, MD, Kyoung Yul Seo, MD, PhD. "생체계측치와 각막 곡률의 차이에 따른 인공수정체 삽입 후 굴절 오차의 경향." 대한안과학회지, 54.9(2013): 1345-1352

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제