정상안압녹내장에서 서로 다른 빛간섭단층촬영기를 이용한 망막신경섬유층의 측정 비교

이용수 2

영문명
Comparison of RNFL Thickness Measured by Two Different Kind of OCT in NTG Patients
발행기관
대한안과학회
저자명
한경은 전루민 최규룡,Kyung-Eun Han, MD, Roo Min Jun, MD, Kyu-Ryong Choi, MD
간행물 정보
『대한안과학회지』Ophthalmological Society,volume50,number12, 1853~1859쪽, 전체 7쪽
주제분류
의약학 > 기타의약학
파일형태
PDF
발행일자
2009.12.15
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: To compare retinal nerve fiber layer (RNFL) thicknesses with two types of OCT in patients with normal tension glaucoma (NTG) and early NTG. Methods: We evaluated the RNFL thicknesses of 101 eyes in 101 patients using Fourier domain OCT and time domain OCT. We compared the measured RNFL thicknesses according to the subject groups and the type of OCT. We calculated the area under the receiver operating characteristic curve (AUROC) to determine the best parameters with which to make a diagnosis of NTG or early NTG. Results: The RNFL thicknesses measured by 3D OCT were greater than that measured by Stratus OCT for all of the groups. The RNFL thickness in each group was statistically significantly different in the superior quadrant, the inferior quadrant, and the 1 and 2 o’clock positions when using 3D OCT. It was statistically significantly different in the superior, temporal, and inferior quadrant, as well as the 1, 7, 8, 9, 10 and 11 o’clock positions when using Stratus OCT. The largest AUROC was found for the inferior quadrant thickness (0.773) using Stratus OCT and the 1 o’clock thickness (0.712) using 3D OCT when comparing normal patients and those with suspected NTG. The largest AUROC was found for the inferior quadrant thickness (0.888) using Stratus OCT and the superior quadrant thickness (0.802) using 3D OCT when comparing normal patients and those with early NTG. The AUROC was greater in the temporal and inferior quadrants and in the 6, 7, 8, 9 and 10 o’clock thicknesses using Stratus OCT compared to the 3D OCT in differentiating patients with suspected NTG from normal patients. The AUROC found using 3D OCT compared to the Stratus OCT was greater only in the 1 o’clock thickness (p<0.05). The AUROC differentiating patients with early NTG from normal patients was greater in the temporal, inferior, nasal quadrant, and in the 5, 6, 7, 8, 9, 10 and 11 o’clock positions using the Stratus OCT compared to the 3D OCT (p<0.05). Conclusions: The RNFL thicknesses measured using 3D OCT were generally greater than those measured using Stratus OCT. The largest AUROCs for differentiating patients with suspected NTG and early NTG from normal patients were in the 1 o’clock position and the superior quadrant RNFL thickness using 3D OCT and the inferior quadrant RNFL thickness using Stratus OCT. The AUROCs using the 3D OCT parameters were less than those from the Stratus OCT when comparing normal patients and those with suspected or early NTG. J Korean Ophthalmol Soc 2009;50(12):1853-1859

목차

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

한경은,전루민,최규룡,Kyung-Eun Han, MD, Roo Min Jun, MD, Kyu-Ryong Choi, MD. (2009).정상안압녹내장에서 서로 다른 빛간섭단층촬영기를 이용한 망막신경섬유층의 측정 비교. 대한안과학회지, 50 (12), 1853-1859

MLA

한경은,전루민,최규룡,Kyung-Eun Han, MD, Roo Min Jun, MD, Kyu-Ryong Choi, MD. "정상안압녹내장에서 서로 다른 빛간섭단층촬영기를 이용한 망막신경섬유층의 측정 비교." 대한안과학회지, 50.12(2009): 1853-1859

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제