안축장 측정을 위한 접촉성 및 침수성 초음파 생체계측법의 비교

이용수 2

영문명
Comparative Analysis of Contact and Immersion Technique in Ultrasonographic Biometry
발행기관
대한안과학회
저자명
임재원 강수연 김효명,Jay Won Rhim, MD, Su Yeon Kang, MD, Hyo Myoung Kim, MD, PhD
간행물 정보
『대한안과학회지』Ophthalmological Society,volume50,number12, 1795~1799쪽, 전체 5쪽
주제분류
의약학 > 기타의약학
파일형태
PDF
발행일자
2009.12.15
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: To establish the accuracy of the newly released biometer Ocuscan RxPⓇ (Alcon, USA) by comparison with the established Ultrasonic Biometer Model 820Ⓡ (Allergan Humphrey, USA), and to compare the accuracy of contact and immersion biometries. Methods: This is a prospective study involving 27 patients (40 eyes) who were scheduled for cataract surgery and had axial lengths measured with an Ocuscan RxPⓇ biometer using both contact (Method 1) and immersion (Method 2) techniques. As a reference, a contact type Ultrasonic biometer 820Ⓡ (Method 3) was also used. IOL(Intraocular Lens) power for the cataract surgery was calculated using this result. An axial length which would have caused no post-operative refractive error was reversely calculated from the difference of target diopter and post-operative refractive error. This length was compared with the axial lengths obtained via Methods 1, 2 and 3. Results: The means and standard deviations for the measurement sets were compared. Methods 1 and 2 showed no significant difference (23.22±0.68, 23.24±0.69 mm, p=0.55). The axial length measured by Method 3 was 23.32±0.67 mm. The difference between the target refraction and post-operative refractive error was 0.29±0.60D. The axial length was reversely calculated from the difference (23.07±0.84 mm). The differences between the reversely calculated axial lengths and those of Methods 1, 2 and 3 were 0.15± 0.31, 0.17±0.31 and 0.24±0.28 mm, respectively. Conclusions: Biometric results from Methods 1 and 2 caused less refractive error than did Method 3. The contact and immersion methods are both accurate for IOL power calculation if performed by a well-skilled examiner. J Korean Ophthalmol Soc 2009;50(12):1795-1799

목차

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

임재원,강수연,김효명,Jay Won Rhim, MD, Su Yeon Kang, MD, Hyo Myoung Kim, MD, PhD. (2009).안축장 측정을 위한 접촉성 및 침수성 초음파 생체계측법의 비교. 대한안과학회지, 50 (12), 1795-1799

MLA

임재원,강수연,김효명,Jay Won Rhim, MD, Su Yeon Kang, MD, Hyo Myoung Kim, MD, PhD. "안축장 측정을 위한 접촉성 및 침수성 초음파 생체계측법의 비교." 대한안과학회지, 50.12(2009): 1795-1799

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제