본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

백내장 종류에 따른 단파장시야측정 결과의 차이

이용수 3

영문명
The Differences in Results of Short Wavelength Automated Perimetry According to Lens Opacities
발행기관
대한안과학회
저자명
하병진 김대홍 주영광 이은석 홍영재,Byoung-Jin Ha, M.D., Dae-Hong Kim, M.D., Young-Kwang Chu, M.D., Eun-Suk Lee, M.D., Young-Jae Hong, M.D.
간행물 정보
『대한안과학회지』Ophthalmological Society,volume46,number10, 1663~1668쪽, 전체 6쪽
주제분류
의약학 > 기타의약학
파일형태
PDF
발행일자
2005.10.31
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: Perimetric examination plays an important role in the diagnosis of glaucoma, which is among the leading causes of blindness worldwide. Several examination methods have been developed for early detection of glaucoma. Among those, short-wavelength automated perimetry (SWAP) is the most widely investigated. In this study, the effects of nuclear opacities on SWAP were examined. Methods: Lens opacities were divided into cortical and nuclear opacity groups ; each group consisted of fifteen eyes. The eyes studied underwent standard white-on-white perimetry and SWAP exams before and after cataract operation. The differences in the results of the examinations were compared between the two opacity groups. The t test was used for comparing the data. Results: In the cortical opacity group, the average difference between the mean deviation before and after the operation was 5.46dB in white-on-white perimetry and 5.02dB in SWAP. In the nuclear opacity group, the average difference between the mean deviation before and after the operation was 4.01dB in white-on-white perimetry and 10.82dB in SWAP. There was no statistically significant difference in the cortical opacity group (p=0.6575). However, there was a statistically significant difference in the nuclear opacity group (p<0.0001). Conclusions: In clinical situations, more caution should be taken when interpreting the SWAP results of nuclear cataract patients in order to make an accurate decision.

목차

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

하병진,김대홍,주영광,이은석,홍영재,Byoung-Jin Ha, M.D., Dae-Hong Kim, M.D., Young-Kwang Chu, M.D., Eun-Suk Lee, M.D., Young-Jae Hong, M.D.. (2005).백내장 종류에 따른 단파장시야측정 결과의 차이. 대한안과학회지, 46 (10), 1663-1668

MLA

하병진,김대홍,주영광,이은석,홍영재,Byoung-Jin Ha, M.D., Dae-Hong Kim, M.D., Young-Kwang Chu, M.D., Eun-Suk Lee, M.D., Young-Jae Hong, M.D.. "백내장 종류에 따른 단파장시야측정 결과의 차이." 대한안과학회지, 46.10(2005): 1663-1668

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제