하승모근 등척성 운동방법에 따른 근두께 변화량 비교 및 초음파 영상의 신뢰도 연구

이용수 221

영문명
A Comparison of Change in Thickness for Lower Trapezius Muscle During Lower Trapezius Muscle Isometric Exercise and Reliability of Ultrasound Imaging
발행기관
한국전문물리치료학회
저자명
송우리(Woo-ri Song) 김선엽(Suhn-yeop Kim) 장현정(Hyun-jeong Jang)
간행물 정보
『한국전문물리치료학회지』한국전문물리치료학회지 제19권 제3호, 31~39쪽, 전체 9쪽
주제분류
의약학 > 의학일반
파일형태
PDF
발행일자
2012.09.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

The lower trapezius muscle is an important stabilizer and primary mover of the scapula. The potential use of ultrasound imaging to evaluate scapular muscle function warrants investigation. The purpose of this study is to use ultrasound imaging for determining the effectiveness of 4 different isometric exercises for maximally activating the lower trapezius muscles in healthy subjects. Twenty-eight (14 men and 14 women) volunteers were recruited for this study. Thickness measurements of the lower trapezius muscles were recorded during 4 exercises: latissimus pulldown (LP), prone V -raise (PV), prone row (PR), and modified prone cobra (JVIP). Lower trapezius muscle thickness was measured 3 times by 2 investigators at a point 3 cm lateral to the lateral edge of the T8 spinous process. The order of 4 exercise execution was randomized for each participant. To identify statistical significance, one-way ANOVA with repeated measures was used with the significance level of .05. Intraclass correlation coefficient (ICC) for intra -reliability was .86 ~ .98 and inter-rater reliability .83 ~.96 for the lower trapezius, respectively (p<.01) Thickness changes in the lower trapezius muscles between the relaxed and contracted states in men were as follows: LP (7.37: ±2.68 mm, 182%), MP (4.69: ±1.74 mm, 167%), PV (4.52: ±1.47 mm, 149%), and PR (3.84: ±1.72 mm, 133%). In women the values were as follows: LP (4.64: ±1.24 mm, 163%), MP (2.79: ±.81 mm, 131%), PV (2.78: ±.85 mm, 129%), and PR (2.21: ±1.26 mm, 100%). Thickness of the lower trapezius muscles significantly differed between exercises in both the gender (p<.01) The LP was the most effective exercise for increasing the activation of the lower trapezius muscle in both the gender. We recommend performing the LP exercise for strengthening the lower trapezius muscles.

목차

Abstract
Ⅰ. 서론
Ⅱ. 연구방법
Ⅲ. 결과
Ⅳ. 고찰
Ⅴ. 결론
인용문헌

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

송우리(Woo-ri Song),김선엽(Suhn-yeop Kim),장현정(Hyun-jeong Jang). (2012).하승모근 등척성 운동방법에 따른 근두께 변화량 비교 및 초음파 영상의 신뢰도 연구. 한국전문물리치료학회지, 19 (3), 31-39

MLA

송우리(Woo-ri Song),김선엽(Suhn-yeop Kim),장현정(Hyun-jeong Jang). "하승모근 등척성 운동방법에 따른 근두께 변화량 비교 및 초음파 영상의 신뢰도 연구." 한국전문물리치료학회지, 19.3(2012): 31-39

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제