본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

The effects of different pilot-drilling methods on the mechanical stability of a mini-implant system at placement and removal: a preliminary study

이용수 0

영문명
The effects of different pilot-drilling methods on the mechanical stability of a mini-implant system at placement and removal: a preliminary study
발행기관
대한치과교정학회
저자명
Il-Sik Cho Hye Ran Choo Seong-Kyun Kim Yun-Seob Shin Duck-Su Kim Seong-Hun Kim Kyu-Rhim Chung John C
간행물 정보
『The Korean Journal of Orthodontics』제41권 제5호, 354~360쪽, 전체 7쪽
주제분류
의약학 > 기타의약학
파일형태
PDF
발행일자
2011.10.31
무료

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Objective: To investigate the effects of different pilot-drilling methods on the biomechanical stability of self-tapping mini-implant systems at the time of placement in and removal from artificial bone blocks. Methods: Two types of artificial bone blocks (2-mm and 4-mm, 102-pounds per cubic foot [102-PCF] polyurethane foam layered over 100-mm, 40-PCF polyurethane foam) were custom-fabricated. Eight mini-implants were placed using the conventional motor-driven pilot-drilling method and another 8 mini-implants were placed using a novel manual pilot-drilling method (using a manual drill) within each of the 2-mm and 4-mm layered blocks. The maximum torque values at insertion and removal of the mini-implants were measured, and the total energy was calculated. The data were statistically analyzed using linear regression analysis. Results: The maximum insertion torque was similar regardless of block thickness or pilot-drilling method. Regardless of the pilot-drilling method, the maximum removal torque for the 4-mm block was statistically higher than that for the 2-mm block. For a given block, the total energy at both insertion and removal of the mini-implant for the manual pilot-drilling method were statistically higher than those for the motor-driven pilot-drilling method. Further, the total energies at removal for the 2-mm block was higher than that for the 4-mm block, but the energies at insertion were not influenced by the type of bone blocks. Conclusions: During the insertion and removal of mini-implants in artificial bone blocks, the effect of the manual pilot-drilling method on energy usage was similar to that of the conventional, motor-driven pilot-drilling method.

목차

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

Il-Sik Cho,Hye Ran Choo,Seong-Kyun Kim,Yun-Seob Shin,Duck-Su Kim,Seong-Hun Kim,Kyu-Rhim Chung,John C. (2011).The effects of different pilot-drilling methods on the mechanical stability of a mini-implant system at placement and removal: a preliminary study. The Korean Journal of Orthodontics, 41 (5), 354-360

MLA

Il-Sik Cho,Hye Ran Choo,Seong-Kyun Kim,Yun-Seob Shin,Duck-Su Kim,Seong-Hun Kim,Kyu-Rhim Chung,John C. "The effects of different pilot-drilling methods on the mechanical stability of a mini-implant system at placement and removal: a preliminary study." The Korean Journal of Orthodontics, 41.5(2011): 354-360

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제