학술논문
Low-shrinking composites. Are they reliable for bonding orthodontic retainers?
이용수 0
- 영문명
- Low-shrinking composites. Are they reliable for bonding orthodontic retainers?
- 발행기관
- 대한치과교정학회
- 저자명
- Tancan Uysal Caglar Sakin Talal Al-Qunaian
- 간행물 정보
- 『The Korean Journal of Orthodontics』제41권 제1호, 51~58쪽, 전체 8쪽
- 주제분류
- 의약학 > 기타의약학
- 파일형태
- 발행일자
- 2011.02.27
무료
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.
국문 초록
영문 초록
Objective: To evaluate the shear bond strength (SBS), fracture mode, wire pull out (WPO) resistance and microleakage between low-shrinking and conventional composites used as a lingual retainer adhesive. Methods: A total of 120 human mandibular incisor teeth, extracted for periodontal reasons, were collected. Sixty of them were separated into two groups. To determine the SBS, either Transbond-LR (3M-Unitek) or Silorane (3M-Espe) was applied to the lingual surface of the teeth by packing the material into standard cylindrical plastic matrices (Ultradent) to simulate the lingual retainer bonding area. To test WPO resistance, 20 samples were prepared for each composite where the wire was embedded in the composite materialand cured. Then tensile stress was applied until failure of the composite occurred. The remaining 60 teeth were divided into two groups and multi-stranded 0.0215-inch diameter wire was bonded with the same composites. Microleakage was evaluated by the dye penetration method. Statistical analyses were performed by Wilcoxon, Pearson chi-square, and Mann-Whitney-U tests at p < 0.05 level. Results: The SBS and WPO results were not statistically significant between the two groups. Significant differences were found between the groups in terms of fracture mode (p < 0.001). Greater percentages of the fractures showed mix type failure (85%) for Silorane and adhesive (60%) for Transbond-LR. Microleakage values were lower in low-shrinking composite than the control and this difference was found to be statistically significant (p < 0.001). Conclusions: Low-shrinking composite produced sufficient SBS, WPO and microleakage values on the etched enamel surfaces, when used as a lingual retainer composite. (Korean J Orthod 2011;41(1):51-58)
목차
해당간행물 수록 논문
- 교정용 마이크로 임플란트의 나사산 디자인 최적화
- 치근접촉이 마이크로 임플란트 인접골 응력에 미치는 영향에 대한 유한요소해석
- Low-shrinking composites. Are they reliable for bonding orthodontic retainers?
- Treatment of unilateral buccal crossbite with mandibular symphyseal distraction osteogenesis
- Identification of tumor necrosis factor-α levels around miniscrews during canine distalization
- 항미생물제제를 포함한 self-etching primer로 접착한 세라믹 브라켓의 전단 결합 강도
- 조화로운 측모를 가진 몽골인과 한국인 성인 정상교합자의 측모두부계측방사선학적 비교 연구
참고문헌