Titanium Implant의 Removal Torque에 관한 연구
이용수 2
- 영문명
- 발행기관
- 대한치과이식임플란트학회
- 저자명
- 이준석 김영수
- 간행물 정보
- 『Journal of Dental Implant Research』제13권 제1호, 127~148쪽, 전체 22쪽
- 주제분류
- 의약학 > 의학일반
- 파일형태
- 발행일자
- 1993.12.31
5,440원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.
국문 초록
영문 초록
The concept of biologic attachment of load-bearing implants has developed over the past decades as
an alternative to the difficulties associated with long term implantation using mechanical fixation and
bone cement. The choice of implant material is also as critical an element as site preparation or
insertion procedure. The properties of implants that affect host tissue responses are not limited to
chemical composition alone, but also include shape, surface characteristics, site of implantation, and
mechanical interaction with host tissues. Initial mechanical interlocking prevents micromotion and
may be a prerequisite for direct bone apposition. A hard tightening of screws does not necessarily
mean a stronger fixation and final tightening of the fixtures is dependent on the experience of the
operator. Removal torque is lower than insertion torque. The purpose of this study was to investigate
differences in the removal torques at the bone-implant interface of polished and sandblasted Titanium.
This experiment will give insight into important factors that must be considered when interpreting in
vivo screwing forces on implants during the connection of the transmucosal abutments. We evaluated
the significance of different surface textures by comparison of the withdrawal forces necessary for
removal of otherwise identical rough and polished implants of Titanium and also evaluated interfacial
response on the light microscopic level to implant surface. And the priority of the area of insertion on
osseointegration were evaluated. 9 Titanium implants - among them, 3 were for the developmental - of
either a smooth or rough surface finish were inserted in the dog mandible in the right side. 3 months
later Kanon Torque Gauge was used to unscrew the implants.
The results were as follows :
1. No significant difference was seen in the removal torque due to variation in surface treatment, 23
Ncm for the sandblasted and 23.33 Ncm for the polished surface (p > 0.05).
2. Implants in the anterior (25 Ncm) mandible showed better resistance to unscrewing in
comparison to ones in the posterior (18 Ncm) region (p < 0.05).
3. Developmental fixtures (22 Ncm) had similar pullout strength to the control group (p > 0.05).
목차
서 론
연구 대상 및 방법
연구 성적
총괄 및 고안
결 론
참고문헌
키워드
해당간행물 수록 논문
- 학술 강연회 연제 초록
- 치과임프란트 보철시 치관재료의 차이에 따른 응력 분산의 이차원 유한요소법적 연구
- 1993년 학술집담회 초록
- 치과임프란트 보철에 있어 경사지대주의 경사각에 따른 응력의 유한요소법적 분석
- 가토의 경골 및 슬관절에 임프란트 식립시 Overtightening이 Removal Torque에 미치는 영향
- Titanium Implant의 Removal Torque에 관한 연구
- 치과임프란트 고정체의 형태 및 직경의 차이에 따른 응력 분산의 삼차원 유한요소 분석적 연구
- 제 3 회 학술대회 및 연수회 초록
- 성견의 치주질환 이환 발치와에 이식된 Hydroxyapatite 피개이식체 주위의 신생골 형성에 관한 연구
- 人事의 말씀
- Titanium disc에 도포한 부착단백질이 사람 치은 조섬유세포의 부착 및 증식에 미치는 영향
참고문헌
관련논문
의약학 > 의학일반분야 BEST
- 교육전담간호사가 주도하는 임상현장교육 프로그램이 신규 간호사의 간호업무성과와 교육 만족도에 미치는 효과
- 일반인을 위한 해부학 만화
- 중환자실 간호사의 간호근무환경과 직무 스트레스가 간호업무성과에 미치는 영향
의약학 > 의학일반분야 NEW
- 안구내용적출 시 자가통증조절장치를 이용한 선제적 전신 진통제의 효과
- 빅데이터를 이용한 COVID-19 백신 접종 후 발생한 안과적 이상사례에 대한 고찰
- 만성 중심장액맥락망막병증에서 국소레이저광응고술과 유리체 내 베바시주맙 주입술의 효과 비교
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!