학술논문
한국어의 음향 특성을 고려한 보청기 처방법과 기존 처방법의 비교
이용수 62
- 영문명
- Comparison of a Hearing Aid Fitting Formula Based on Korean Acoustic Characteristics and Existing Fitting Formulae
- 발행기관
- 한국청각언어재활학회
- 저자명
- In-Ki Jin,Kyoungwon Lee,Jinsook Kim,Dongwook Kim,Junil Sohn,Junghak Lee
- 간행물 정보
- 『Audiology and Speech Research』Audiology and Speech Research 제13권 제3호, 216~221쪽, 전체 6쪽
- 주제분류
- 사회과학 > 교육학
- 파일형태
- 발행일자
- 2017.07.31
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.
국문 초록
영문 초록
Purpose: Most existing hearing aid (HA) fitting formulae were developed based on English. However, Korean language has different
acoustic characteristics compared to English. This study aimed to develop Korean language-specific hearing aid fitting formula (Hallym Audiology
Institute-version 1, HAI-v1) and to compare speech perception, clarity, and overall preference between the HAI-v1 and established
fitting formulae [National Acoustic Laboratories’ nonlinear fitting procedure, version 2 (NAL-NL2) and Desired Sensation Level, version 5.0
(DSL5.0)]. Methods: Gains for the HAI-v1 were determined to reach the gain around the medium to the two-thirds portion in the dynamic
range of conversational speech level for soft, medium, and loud levels using loudness growth for Koreans who have sensorineural hearing
loss (SNHL). Twenty-four people with SNHL participated in this study. Reception thresholds of sentences (RTSs) and preferences (clarity
and overall preference) were evaluated, once with HAI-v1 setting, once with NAL-NL2 setting, and once with DSL5.0 setting, in random
order. Then, results of RTSs and preferences across HA fitting formulae were compared. Results: There were no statistical differences
for RTSs with and without noise in all HA fitting formulae. For clarity, more participants preferred sounds with HAI-v1 or NAL-NL2 than
sounds with DSL5.0. For overall preference, more participants preferred sounds with HAI-v1 than sounds with NAL-NL2 or DSL5.0. Conclusion:
Results of this study suggest that language-specific HA fitting formula may provide better HA outcomes for people who use
different languages.
목차
INTRODUCTION
MATERIALS AND METHODS
RESULTS
REFERENCES
키워드
해당간행물 수록 논문
- Effect of Daily Communication Behaviors on Cognitive and Language Abilities of the Elderly
- 초고막형 보청기를 통한 폐쇄효과의 감소와 전화 사용 및 미용상의 만족도 향상 사례
- 영유아 청각 및 의사소통 행동 체크리스트의 신뢰도와 타당도 검증
- Influence of Upper Frequency Boundary on Consonant Perception in Normal Hearing and Cochlear Implant Adults
- 발달장애인 말뭉치 구축을 위한 예비연구: 언어재활사의 설문 반응을 중심으로
- 청각학 학과인증제를 위한 교육환경 조사 연구
- 한국어의 음향 특성을 고려한 보청기 처방법과 기존 처방법의 비교
- 이명의 요양과 장애 보상: 전역 군인의 군 소음으로 인한 이명 장애를 중심으로
- 성심농아재활원생들의 청력 실태 조사연구
참고문헌
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!