본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

Characteristics of Mechanical Outputs During Rowing Motion: Comparison Between Fixed and Slide Rowing Ergometers

이용수 0

영문명
발행기관
대한운동학회
저자명
Hyunchul Yoon Natsumi Furuta Kazuo Funato
간행물 정보
『아시아 운동학 학술지』제27권 제1호, 3~10쪽, 전체 8쪽
주제분류
예술체육 > 체육
파일형태
PDF
발행일자
2025.01.31
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

OBJECTIVES This study compared the mechanical outputs and lower joint kinematics during rowing motion using fixed and slide-type rowing ergometers to clarify the slide type's characteristics. METHODS Junior rowers performed a simulated 2000m race pace under two ergometer conditions. Rowing motion was filmed by a high-speed video camera (200 fps) from right angles beside the subject and changes in Hip and knee joint angles were measured. Spatiotemporal parameters as well as force output from the handle and stretcher and joint angle kinematics at 500m spot calculated. RESULTS In the 2000m time trial, the two conditions showed no significant difference. However, significant differences were observed in the maximum stretcher force, with the slide-type rowing ergometer showing higher values than the fixed-type rowing ergometer. On the other hand, greater values in handle force were found for the fixed-type rowing ergometer than slide-type rowing ergometer greater. Greater rate of force development for the handle and stretcher were observed in the slide-type rowing ergometer condition. No significant differences were observed in angular changes between the two conditions, but knee and hip maximum angular accelerations were significantly higher in the slide-type rowing ergometer condition. Higher stretcher force in slide-type rowing ergometer at the beginning of the stroke is characterized as the influence of maximal angular acceleration in both knee and hip joint extensions, causing high rate of force development of handle and stretcher forces in the initial phase of the drive. As a result, the muscle groups including the biarticular muscles around hip and knee joints may work in coordination to exert significant force, a defining characteristic of the slide-type rowing ergometer. CONCLUSIONS The fix-type rowing can be used effectively to strengthen the maximum handle pull strength, mainly upper extremity. On the other hand, slide-type rowing can be used effectively to strengthen the maximum stretcher force as well as it’s rate of force development, which might be similar force output of lower extremity as performed during on-water rowing.

영문 초록

목차

Introduction
Material and Methods
Results
Discussion
Conclusions
Conflicts of Interest
References

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

Hyunchul Yoon,Natsumi Furuta,Kazuo Funato. (2025).Characteristics of Mechanical Outputs During Rowing Motion: Comparison Between Fixed and Slide Rowing Ergometers. 아시아 운동학 학술지, 27 (1), 3-10

MLA

Hyunchul Yoon,Natsumi Furuta,Kazuo Funato. "Characteristics of Mechanical Outputs During Rowing Motion: Comparison Between Fixed and Slide Rowing Ergometers." 아시아 운동학 학술지, 27.1(2025): 3-10

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제