CA 19-9 결과보고 개선을 위한 One step 방식과 Two step 방식의 비교에 관한 연구

이용수 0

영문명
A Study on the Comparison of One Step Method and Two Step Method to Improve Reporting of CA 19-9 Results
발행기관
대한핵의학기술학회
저자명
안재석(Jae-Seok An) 김지나(Ji-Na Kim) 박광서(Kwang-Seo Park) 주은빛(Eun-Bit Joo) 윤상혁(Sang-Hyuk Yoon) 김윤철(Yoon-Cheol Kim)
간행물 정보
『핵의학기술』Vol.28 No.1, 81~87쪽, 전체 7쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2024.05.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: CA 19-9 is the most widely used tumor marker for the diagnosis of digestive system tumor, especially pancreatic and biliary tract cancer. This study was conducted to improve the result value near reference range by comparing the reagents of CA 19-9 one step method and two step method. In addition, it was intended to establish a standard for selecting reagents. Material and Methods: 120 patients who visited the National Cancer Center in 2023 were selected as subjects for this study. The reagents used in the study were CA 19-9 IRMA kits (Shinjin, Korea) and three types of reagents were compared. Two step method reagent that is currently being used (A), one step method reagent (B) and two step method reagent improved by request (C) were compared and regression analysis was performed on their data. And we also performed recovery test, linearity test and hook effect test for each reagent. Result: There were 46 cases of reagent B in which the concentration value was lower than the result measured in reagent A that was previously used, and 77 cases of reagent C. As a result of regression analysis of reagents A, B, and C, the coefficients of determination of reagents A and B, reagents A and C, and reagents B and C were 0.653, 0.577, and 0.875. In the recovery rate test and the linearity test, the results of all reagents were good, and in the hook effect test, reagent B showed a hook effect at a low value. Conclusion: The improved reagent C appears to have been improved based on the concentration value of reagent B, which the manufacturer judged to be more stable at low concentrations. The hook effect in reagent B can be a fatal reason for disqualification when selecting reagents in general patient samples which high-concentration samples appear frequently. The first improved reagent C will be able to be used once it is confirmed that it has more stability for various concentration values.

목차

서론
대상 및 방법
결과
고찰 및 결론
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

안재석(Jae-Seok An),김지나(Ji-Na Kim),박광서(Kwang-Seo Park),주은빛(Eun-Bit Joo),윤상혁(Sang-Hyuk Yoon),김윤철(Yoon-Cheol Kim). (2024).CA 19-9 결과보고 개선을 위한 One step 방식과 Two step 방식의 비교에 관한 연구. 핵의학기술, 28 (1), 81-87

MLA

안재석(Jae-Seok An),김지나(Ji-Na Kim),박광서(Kwang-Seo Park),주은빛(Eun-Bit Joo),윤상혁(Sang-Hyuk Yoon),김윤철(Yoon-Cheol Kim). "CA 19-9 결과보고 개선을 위한 One step 방식과 Two step 방식의 비교에 관한 연구." 핵의학기술, 28.1(2024): 81-87

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제