CA 19-9 결과보고 개선을 위한 One step 방식과 Two step 방식의 비교에 관한 연구
이용수 0
- 영문명
- A Study on the Comparison of One Step Method and Two Step Method to Improve Reporting of CA 19-9 Results
- 발행기관
- 대한핵의학기술학회
- 저자명
- 안재석(Jae-Seok An) 김지나(Ji-Na Kim) 박광서(Kwang-Seo Park) 주은빛(Eun-Bit Joo) 윤상혁(Sang-Hyuk Yoon) 김윤철(Yoon-Cheol Kim)
- 간행물 정보
- 『핵의학기술』Vol.28 No.1, 81~87쪽, 전체 7쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2024.05.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

국문 초록
영문 초록
Purpose: CA 19-9 is the most widely used tumor marker for the diagnosis of digestive system tumor, especially pancreatic and biliary tract cancer. This study was conducted to improve the result value near reference range by comparing the reagents of CA 19-9 one step method and two step method. In addition, it was intended to establish a standard for selecting reagents.
Material and Methods: 120 patients who visited the National Cancer Center in 2023 were selected as subjects for this study. The reagents used in the study were CA 19-9 IRMA kits (Shinjin, Korea) and three types of reagents were compared. Two step method reagent that is currently being used (A), one step method reagent (B) and two step method reagent improved by request (C) were compared and regression analysis was performed on their data. And we also performed recovery test, linearity test and hook effect test for each reagent.
Result: There were 46 cases of reagent B in which the concentration value was lower than the result measured in reagent A that was previously used, and 77 cases of reagent C. As a result of regression analysis of reagents A, B, and C, the coefficients of determination of reagents A and B, reagents A and C, and reagents B and C were 0.653, 0.577, and 0.875. In the recovery rate test and the linearity test, the results of all reagents were good, and in the hook effect test, reagent B showed a hook effect at a low value.
Conclusion: The improved reagent C appears to have been improved based on the concentration value of reagent B, which the manufacturer judged to be more stable at low concentrations. The hook effect in reagent B can be a fatal reason for disqualification when selecting reagents in general patient samples which high-concentration samples appear frequently. The first improved reagent C will be able to be used once it is confirmed that it has more stability for various concentration values.
목차
서론
대상 및 방법
결과
고찰 및 결론
REFERENCES
해당간행물 수록 논문
- Incidentally detected abnormal finding of femoral bone density image due to treatment of postoperative lymphatic leakage
- Incidentally detected abnormal finding of femoral bone mineral densitometry due to paraffin injections for buttock augmentation
- Synthetic Approach to 99mTc-labeled SPECT Radiotracers with Multi-nitroimidazoles for Hypoxia
- The Effect of Contrast Agent on the Change of Hepatic Uptake of 99mTc-Mebrofenin in Patients with Liver Transplantation
- SiPM PET/CT에서 3D 프린팅 기반 자체제작한 팬텀을 이용한 iMAR 알고리즘 유용성 평가에 관한 연구
- 전신 뼈 검사에서 의료용 신체 고정구의 유용성 평가
- 팬텀을 활용한 PET/CT 장비 별 영상 비교 평가
- CA 19-9 결과보고 개선을 위한 One step 방식과 Two step 방식의 비교에 관한 연구
- 뇌종양진단에 있어 18F-FET Brain PET/CT의 유용성에 대한 고찰
- Satisfaction survey on music listening in patient waiting areas and hallways
- 핵의학 영상에서 계수기반 체적변화 추적에 관한 고찰
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 민간의료보험 해약 의향 영향 요인: 한국 의료 패널 2019년 2기 자료를 이용하여
- 방사선학과 학생 실습환경에 관한 연구: 실습실 내 미세먼지, 휘발성유기화합물 위해도를 중심으로
- 임상에서 사용되는 온장고 온도설정 및 한계점에 대한 고찰
의약학 > 방사선과학분야 NEW
- 추출 크로마토그래피를 이용한 55Fe와 59/63Ni의 화학분리 중 목적원소 및 방해원소 거동 특성 연구
- 진단참고 준위를 적용한 선량 변화에 따른 영상 품질의 변화 평가
- 호주 방사선 의료 전문가 면허제도 및 교육과정 고찰: 진단방사선사를 중심으로
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!