본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

핵의학 영상에서 계수기반 체적변화 추적에 관한 고찰

이용수 0

영문명
A Study on the Tracking of Count-Based Volumetric Changes in Nuclear Medicine Imaging
발행기관
대한핵의학기술학회
저자명
김지현(Ji-Hyeon Kim) 이주영(Jooyoung Lee) 박훈희(Hoon-Hee Park)
간행물 정보
『핵의학기술』Vol.28 No.1, 57~69쪽, 전체 13쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2024.05.30
4,360

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: Quantitative analysis through count measurement in nuclear medicine planar images is limited by analysis techniques that are useful for obtaining various clinical information or by organ overlap or artifacts in actual clinical practice. On the other hand, the use of SPECT tomography images is quantitative analysis using volume rather than planar, which is not only free from problems such as projection overlap, but also has excellent quantitative accuracy. In the use of developing SPECT quantitative analysis technology, this study aims to compare the accuracy of quantitative analysis between ROI of the conventional planar images and VOI of the SPECT tomographic images in evaluating the count change happened by the volume change of the source. Materials and Methods: A 99mTcO4 - source(200.17 MBq) was filled with sterilized water in the syringe to create a phantom with an inner diameter volume of 60 cc, and a planar image and a SPECT image were obtained by reducing the volume by 15 cc (25%) respectively. ROI and VOI(threshold: 1~45%, 5% interval) were set for each image obtained to estimate true count and measure the total count, and compared with the preseted volumetric change rate(%). Results: When volume changes of 25%, 50%, and 75% occurred in the initial volume of 60 cc(100%) of the phantom, the average count changes of the measured planar image were 26.8%, 53.2%, 77.5%, and the average count changes of the SPECT image were 24.4%, 50.9%, and 76.8%. In this case, the VOI size(cm3) set showed an average change rate of 25.4%, 51.1%, and 76.6%. The highest threshold value for the accuracy of radioactive concentration by VOI size (average error -1.03%) was 35%, and the VOI size of the same threshold had an error of -17.1% on average compared to the actual volume. Conclusion: On average, the count-based volumetric change rate in nuclear medicine images was able to track changes more accurately using VOI than ROI, but there was no significant difference with relatively similar value. However, the accuracy of radioactive concentration according to individual VOI sizes did not match, but it is considered that a relatively accurate quantitative analysis can be expected when the size of VOI is set smaller than the actual volume.

목차

서론
대상 및 방법
결 과
고 찰
결 론
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

김지현(Ji-Hyeon Kim),이주영(Jooyoung Lee),박훈희(Hoon-Hee Park). (2024).핵의학 영상에서 계수기반 체적변화 추적에 관한 고찰. 핵의학기술, 28 (1), 57-69

MLA

김지현(Ji-Hyeon Kim),이주영(Jooyoung Lee),박훈희(Hoon-Hee Park). "핵의학 영상에서 계수기반 체적변화 추적에 관한 고찰." 핵의학기술, 28.1(2024): 57-69

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제