핵의학 영상에서 계수기반 체적변화 추적에 관한 고찰
이용수 4
- 영문명
- A Study on the Tracking of Count-Based Volumetric Changes in Nuclear Medicine Imaging
- 발행기관
- 대한핵의학기술학회
- 저자명
- 김지현(Ji-Hyeon Kim) 이주영(Jooyoung Lee) 박훈희(Hoon-Hee Park)
- 간행물 정보
- 『핵의학기술』Vol.28 No.1, 57~69쪽, 전체 13쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2024.05.30
4,360원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

국문 초록
영문 초록
Purpose: Quantitative analysis through count measurement in nuclear medicine planar images is limited by analysis techniques that are useful for obtaining various clinical information or by organ overlap or artifacts in actual clinical practice. On the other hand, the use of SPECT tomography images is quantitative analysis using volume rather than planar, which is not only free from problems such as projection overlap, but also has excellent quantitative accuracy. In the use of developing SPECT quantitative analysis technology, this study aims to compare the accuracy of quantitative analysis between ROI of the conventional planar images and VOI of the SPECT tomographic images in evaluating the count change happened by the volume change of the source.
Materials and Methods: A 99mTcO4 - source(200.17 MBq) was filled with sterilized water in the syringe to create a phantom with an inner diameter volume of 60 cc, and a planar image and a SPECT image were obtained by reducing the volume by 15 cc (25%) respectively. ROI and VOI(threshold: 1~45%, 5% interval) were set for each image obtained to estimate true count and measure the total count, and compared with the preseted volumetric change rate(%).
Results: When volume changes of 25%, 50%, and 75% occurred in the initial volume of 60 cc(100%) of the phantom, the average count changes of the measured planar image were 26.8%, 53.2%, 77.5%, and the average count changes of the SPECT image were 24.4%, 50.9%, and 76.8%. In this case, the VOI size(cm3) set showed an average change rate of 25.4%, 51.1%, and 76.6%. The highest threshold value for the accuracy of radioactive concentration by VOI size (average error -1.03%) was 35%, and the VOI size of the same threshold had an error of -17.1% on average compared to the actual volume.
Conclusion: On average, the count-based volumetric change rate in nuclear medicine images was able to track changes more accurately using VOI than ROI, but there was no significant difference with relatively similar value. However, the accuracy of radioactive concentration according to individual VOI sizes did not match, but it is considered that a relatively accurate quantitative analysis can be expected when the size of VOI is set smaller than the actual volume.
목차
서론
대상 및 방법
결 과
고 찰
결 론
REFERENCES
키워드
해당간행물 수록 논문
- Incidentally detected abnormal finding of femoral bone density image due to treatment of postoperative lymphatic leakage
- Incidentally detected abnormal finding of femoral bone mineral densitometry due to paraffin injections for buttock augmentation
- Synthetic Approach to 99mTc-labeled SPECT Radiotracers with Multi-nitroimidazoles for Hypoxia
- The Effect of Contrast Agent on the Change of Hepatic Uptake of 99mTc-Mebrofenin in Patients with Liver Transplantation
- SiPM PET/CT에서 3D 프린팅 기반 자체제작한 팬텀을 이용한 iMAR 알고리즘 유용성 평가에 관한 연구
- 전신 뼈 검사에서 의료용 신체 고정구의 유용성 평가
- 팬텀을 활용한 PET/CT 장비 별 영상 비교 평가
- CA 19-9 결과보고 개선을 위한 One step 방식과 Two step 방식의 비교에 관한 연구
- 뇌종양진단에 있어 18F-FET Brain PET/CT의 유용성에 대한 고찰
- Satisfaction survey on music listening in patient waiting areas and hallways
- 핵의학 영상에서 계수기반 체적변화 추적에 관한 고찰
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 민간의료보험 해약 의향 영향 요인: 한국 의료 패널 2019년 2기 자료를 이용하여
- 방사선학과 학생 실습환경에 관한 연구: 실습실 내 미세먼지, 휘발성유기화합물 위해도를 중심으로
- 임상에서 사용되는 온장고 온도설정 및 한계점에 대한 고찰
의약학 > 방사선과학분야 NEW
- 추출 크로마토그래피를 이용한 55Fe와 59/63Ni의 화학분리 중 목적원소 및 방해원소 거동 특성 연구
- 진단참고 준위를 적용한 선량 변화에 따른 영상 품질의 변화 평가
- 호주 방사선 의료 전문가 면허제도 및 교육과정 고찰: 진단방사선사를 중심으로
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!