DMIDR 장치의 재구성 알고리즘 별 성능 평가

이용수 0

영문명
Performance Evaluation of Reconstruction Algorithms for DMIDR
발행기관
대한핵의학기술학회
저자명
곽인석(In-Suk Kwak) 이혁(Hyuk Lee) 문승철(Seung-Cheol Moon)
간행물 정보
『핵의학기술』Vol.23 No.2, 29~37쪽, 전체 9쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2019.10.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose DMIDR(Discovery Molecular Imaging Digital Ready, General Electric Healthcare, USA) is a PET/CT scanner designed to allow application of PSF(Point Spread Function), TOF(Time of Flight) and Q.Clear algorithm. Especially, Q.Clear is a reconstruction algorithm which can overcome the limitation of OSEM(Ordered Subset Expectation Maximization) and reduce the image noise based on voxel unit. The aim of this paper is to evaluate the performance of reconstruction algorithms and optimize the algorithm combination to improve the accurate SUV(Standardized Uptake Value) measurement and lesion detectability. Materials and Methods PET phantom was filled with 18F-FDG radioactivity concentration ratio of hot to background was in a ratio of 2:1, 4:1 and 8:1. Scan was performed using the NEMA protocols. Scan data was reconstructed using combination of ①VPFX(VUE point FX(TOF)), ②VPHD-S(VUE Point HD+PSF), ③VPFX-S (TOF+PSF), ④QCHD-S-400((VUE Point HD+Q.Clear(β-strength 400)+PSF), ⑤QCFX-S-400(TOF +Q.Clear (β-strength 400)+PSF), ⑥QCHD-S-50(VUE Point HD+Q.Clear(β-strength 50)+PSF) and ⑦QCFX-S-50 (TOF+Q.Clear(β-strength 50)+PSF). CR(Contrast Recovery) and BV(Background Variability) were compared. Also, SNR(Signal to Noise Ratio) and RC(Recovery Coefficient) of counts and SUV were compared respectively. Results VPFX-S showed the highest CR value in sphere size of 10 and 13 ㎜, and QCFX-S-50 showed the highest value in spheres greater than 17 ㎜. In comparison of BV and SNR, QCFX-S-400 and QCHD-S-400 showed good results. The results of SUV measurement were proportional to the H/B ratio. RC for SUV is in inverse proportion to the H/B ratio and QCFX-S-50 showed highest value. In addition, reconstruction algorithm of Q.Clear using 400 of β-strength showed lower value. Conclusion When higher β-strength was applied Q.Clear showed better image quality by reducing the noise. On the contrary, lower β-strength was applied Q.Clear showed that sharpness increase and PVE(Partial Volume Effect) decrease, so it is possible to measure SUV based on high RC comparing to conventional reconstruction conditions. An appropriate choice of these reconstruction algorithm can improve the accuracy and lesion detectability. In this reason, it is necessary to optimize the algorithm parameter according to the purpose.

목차

서론
실험재료 및 방법
결과
고찰
결론
요약
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

곽인석(In-Suk Kwak),이혁(Hyuk Lee),문승철(Seung-Cheol Moon). (2019).DMIDR 장치의 재구성 알고리즘 별 성능 평가. 핵의학기술, 23 (2), 29-37

MLA

곽인석(In-Suk Kwak),이혁(Hyuk Lee),문승철(Seung-Cheol Moon). "DMIDR 장치의 재구성 알고리즘 별 성능 평가." 핵의학기술, 23.2(2019): 29-37

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제