학술논문
PET/CT 검사에서 냉소 인공물 발생 시 산란 제한 보정 알고리즘 적용에 따른 영상 평가
이용수 0
- 영문명
- A study on evaluation of the image with washed-out artifact after applying scatter limitation correction algorithm in PET/CT exam
- 발행기관
- 대한핵의학기술학회
- 저자명
- 고현수(Hyun-Soo Ko) 류재광(Jae-kwang Ryu)
- 간행물 정보
- 『핵의학기술』Vol.22 No.1, 55~66쪽, 전체 12쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2018.05.30
4,240원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

국문 초록
영문 초록
Purpose In PET/CT exam, washed-out artifact could occur due to severe motion of the patient and high specific activity, it results in lowering not only qualitative reading but also quantitative analysis. Scatter limitation correction by GE is an algorism to correct washed-out artifact and recover the images in PET scan. The purpose of this study is to measure the threshold of specific activity which can recovers to original uptake values on the image shown with washed-out artifact from phantom experiment and to compare the quantitative analysis of the clinical patient’s data before and after correction. Materials and Methods PET and CT images were acquired in having no misalignment(D0) and in 1, 2, 3, 4 cm distance of misalignment(D1, D2, D3, D4) respectively, with 20 steps of each specific activity from 20 to 20,000 kBq/ml on ⁶⁸Ge cylinder phantom. Also, we measured the distance of misalignment of foley catheter line between CT and PET images, the specific activity which makes washed-out artifact, SUVₘₑₐₙ of muscle in artifact slice and SUVₘₐₓ of lesion in artifact slice and SUVₘₐₓ of the other lesion out of artifact slice before and after correction respectively from 34 patients who underwent ¹⁸F-FDG Fusion Whole Body PET/CT exam. SPSS 21 was used to analyze the difference in the SUV between before and after scatter limitation correction by paired t-test. Results In phantom experiment, SUVₘₑₐₙ of ⁶⁸Ge cylinder decreased as specific activity of 18F increased. SUVₘₑₐₙ more and more decreased as the distance of misalignment between CT and PET more increased. On the other hand, the effect of correction increased as the distance more increased. From phantom experiments, there was no washed-out artifact below 50 kBq/ml and SUVₘₑₐₙ was same from origin. On D0 and D1, SUVₘₑₐₙ recovered to origin(0.95) below 120 kBq/ml when applying scatter limitation correction. On D2 and D3, SUVₘₑₐₙ recovered to origin below 100 kBq/ml. On D4, SUVₘₑₐₙ recovered to origin below 80 kBq/ml. From 34 clinical patient’s data, the average distance of misalignment was 2.02 cm and the average specific activity which makes washed-out artifact was 490.15 kBq/ml. The average SUVₘₑₐₙ of muscles and the average SUVₘₐₓ of lesions in artifact slice before and after the correction show a significant difference according to a paired t-test respectively(t=-13.805, p=0.000)(t=-2.851, p=0.012), but the average SUVₘₐₓ of lesions out of artifact slice show a no significant difference (t=-1.173, p=0.250). Conclusion Scatter limitation correction algorism by GE PET/CT scanner helps to correct washed-out artifact from motion of a patient or high specific activity and to recover the PET images. When we read the image occurred with washed-out artifact by measuring the distance of misalignment between CT and PET image, specific activity after applying scatter limitation algorism, we can analyze the images more accurately without repeating scan.
목차
서론
실험 대상 및 방법
결과
고찰
결론
요약
REFERENCE
해당간행물 수록 논문
- 뼈 검사 영상과 골반 X선 영상의 결합 유용성 평가
- ¹⁸F-FDG Whole Body PET/CT 수검자의 거리별 선량 변화에 따른 방사선 작업종사자의 유효선량 고찰
- Lung Perfusion scan에서 SPECT-CT의 Q-Metrix방법과 평면영상 결과 산출방법에 대한 비교평가
- Plasma renin activity(PRA) and Active renin concentration(ARC)비교를 통한 ARC 유용성 실험
- Liver PET/MRI 검사 시 MR 기반 호흡 움직임 보정 방법의 유용성 평가
- 재구성 방법(점 확산함수 적용 유무)에 따른 PET/MR 영상 평가
- Thyrogen 투여 후 측정된 Thyroglobulin 농도변화
- 방사성옥소 사용 시 배수 중 방사능농도 분석
- PET/CT 장비와 영상 재구성 차이에 따른 EQ PET을 이용한 표준섭취계수의 평가
- Gamma Camera에 있어 측면 선란선의 영향에 대한 평가
- 타우 PET영상을 위한 ¹⁸F-THK5351의 표지방법 개발
- PET/CT 검사에서 냉소 인공물 발생 시 산란 제한 보정 알고리즘 적용에 따른 영상 평가
- CEA 키트들 간의 성능 평가에 대한 고찰
- 소화기계 Leakage 환자 검사 시 SPECT-CT의 유용성 평가
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 민간의료보험 해약 의향 영향 요인: 한국 의료 패널 2019년 2기 자료를 이용하여
- 의료용 인공지능에 대한 동향 분석 및 방사선사 인식조사
- 임상에서 사용되는 온장고 온도설정 및 한계점에 대한 고찰
의약학 > 방사선과학분야 NEW
- RI 등 사용 허가 대학의 정기 검사 수검 사례: 방사선학과를 대상으로
- 핵의학 갑상샘 팬텀 영상에서 보간법이 초고분해능 ResNet 모델성능에 미치는 영향에 관한 연구
- 방사성동위원소(RI) 폐기물 내 Pb-214, Bi-214 화학 분리를 통한 핵종분석 방법에 관한 연구
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!