학술논문
뼈 검사 영상과 골반 X선 영상의 결합 유용성 평가
이용수 0
- 영문명
- Evaluation of the combination of Bone Scan Image and Pelvic X-ray Image
- 발행기관
- 대한핵의학기술학회
- 저자명
- 이충운(Choong Woon Lee) 유연욱(Yeon Wook You) 김용근(Yong Keun Kim) 원우재(Woo Jae Weon)
- 간행물 정보
- 『핵의학기술』Vol.22 No.1, 23~27쪽, 전체 5쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2018.05.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

국문 초록
영문 초록
Purpose The introduction of bone scan has been reported as a useful tool in the diagnosis, treatment, and treatment response of skeletal disease. The purpose of this study is to improve the anatomical information and tolerance of the bone by combining bone scan and pelvic X-ray without additional radiation exposure. Materials and Methods From November 2015 to August 2016, 236 patients(64 men and 172 women, average age 50.96 ± 15.39 years) take Bone scan and Pelvis AP(Anteroposterior) X-ray scan at the National Cancer Center. The scan equipment was a gamma camera, Symbia Ecam (SIEMENS, Germany), and a digital x-ray, DRS-800 (Listem, Korea). Osirix version 3.8.1 (Osirix, USA) and Stata/SE version 14.0 (StataCorp, USA) were used for image combination and analysis. The patient was intravenously injected with ⁹⁹ᵐTc-DPD (740 MBq), and the scan was performed 2 to 4 hours later. Gamma camera image acquisition were Matrix size 256 × 1024, Zoom 1.00, and scan speed 17 cm/min. The digital X-ray was made with a collimator size of 14”× 17”, 77 kVp (60 to 97 kVp) and an average of 30 mAs (20 to 48). ASIS and pubic symphysis Select virtual points then Combine three virtual points and pelvic contour lines. The acquired images were evaluated by three radiologists who worked for more than 5 years in the nuclear medicine department. Results Of the total 236 patients, 216 (91.53%) were matched. The median and range (min~max) of the age were 67 (46~81) years old in the unmatched group and 52 (22~87) years old in the matched group, The Wilcoxon rank-sum test was performed to determine whether age was different between the two groups. As a result, the age difference between the two groups was statistically significant at p < 0.0001. Of the 64 men, 60 (93.75%) were match and of the 172 women, 156 (93.75%) were match. There was no statistically significant difference according to gender(p = 0.4542). Of the 54 patients without pelvic lesions, 54 (100.00%) were match, and 162 (89.01%) of 182 patients with pelvic lesions were match. There was a statistically significant difference according to the presence of pelvic lesions. Conclusion There are many variables in the combination of bone scan and pelvic X-ray imaging, and the patient's age and pelvic lesion may have some effect on the image combination. This study is expected to be useful for the diagnosis of pelvic osteosarcoma of children without radiation exposure. It is expected that this combination of images will help to develop the nuclear medicine image.
목차
서론
대상 및 방법
결과
결론
요약
REFERENCES
해당간행물 수록 논문
- 뼈 검사 영상과 골반 X선 영상의 결합 유용성 평가
- ¹⁸F-FDG Whole Body PET/CT 수검자의 거리별 선량 변화에 따른 방사선 작업종사자의 유효선량 고찰
- Lung Perfusion scan에서 SPECT-CT의 Q-Metrix방법과 평면영상 결과 산출방법에 대한 비교평가
- Plasma renin activity(PRA) and Active renin concentration(ARC)비교를 통한 ARC 유용성 실험
- Liver PET/MRI 검사 시 MR 기반 호흡 움직임 보정 방법의 유용성 평가
- 재구성 방법(점 확산함수 적용 유무)에 따른 PET/MR 영상 평가
- Thyrogen 투여 후 측정된 Thyroglobulin 농도변화
- 방사성옥소 사용 시 배수 중 방사능농도 분석
- PET/CT 장비와 영상 재구성 차이에 따른 EQ PET을 이용한 표준섭취계수의 평가
- Gamma Camera에 있어 측면 선란선의 영향에 대한 평가
- 타우 PET영상을 위한 ¹⁸F-THK5351의 표지방법 개발
- PET/CT 검사에서 냉소 인공물 발생 시 산란 제한 보정 알고리즘 적용에 따른 영상 평가
- CEA 키트들 간의 성능 평가에 대한 고찰
- 소화기계 Leakage 환자 검사 시 SPECT-CT의 유용성 평가
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 민간의료보험 해약 의향 영향 요인: 한국 의료 패널 2019년 2기 자료를 이용하여
- 의료용 인공지능에 대한 동향 분석 및 방사선사 인식조사
- 임상에서 사용되는 온장고 온도설정 및 한계점에 대한 고찰
의약학 > 방사선과학분야 NEW
- RI 등 사용 허가 대학의 정기 검사 수검 사례: 방사선학과를 대상으로
- 핵의학 갑상샘 팬텀 영상에서 보간법이 초고분해능 ResNet 모델성능에 미치는 영향에 관한 연구
- 방사성동위원소(RI) 폐기물 내 Pb-214, Bi-214 화학 분리를 통한 핵종분석 방법에 관한 연구
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!
