Comparison of Anterior Segment Measurements with a New Multifunctional Unit and Five Other Devices

이용수 0

영문명
Comparison of Anterior Segment Measurements with a New Multifunctional Unit and Five Other Devices
발행기관
대한안과학회
저자명
Bo Yi Kim Ikhyun Jun
간행물 정보
『The Korean Journal of Ophthalmology』Vol.36 No.4, 338~349쪽, 전체 12쪽
주제분류
의약학 > 기타의약학
파일형태
PDF
발행일자
2022.08.31
4,240

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: To evaluate the clinical availability of a multifunctional ocular biometric unit, MR-6000, for simultaneous keratometry, tonometry, topography, and pachymetry evaluation, and compare anterior segment measurements with five other devices: autokeratometer (KR-1), Scheimpflug camera (Pentacam HR), swept-source optical coherence tomography (IOLMaster 700), Placido disk scanning-slit topography (Orbscan II), and noncontact tonometry (FT-1000). Methods: Thirty eyes from thirty patients who visited Severance Hospital for cataract surgery were examined using MR- 6000 and the other devices. The mean keratometry, central corneal thickness (CCT), white-to-white (WTW) distance, and intraocular pressure (IOP) values were compared. Repeated measures analysis of variance, Wilcoxon signed-rank test, intraclass correlation coefficient (ICC), and Bland-Altman plot were used to assess the correlation and agreement between devices. Results: Thirty eyes of thirty patients were evaluated. Statistically significant differences in mean keratometry between MR- 6000, KR-1, Pentacam HR, and IOLMaster 700 were not observed (p > 0.05). All five devices, including Orbscan II, had almost perfect agreement in measuring keratometry (ICC > 0.80, p < 0.05). CCT measured by MR-6000 was significantly different from that of Pentacam HR and Orbscan II measurements (p < 0.05) but correlated with that of Pentacam HR and Orbscan II measurements (ICC > 0.60, p < 0.05). The WTW distance measured by MR-6000 was not significantly different from that measured by IOLMaster 700 but was different from that measured by Orbscan II. IOP measured by MR-6000 was not correlated with FT-1000. Conclusions: Keratometric values obtained through MR-6000 can be used interchangeably with other devices based on good correlation and agreement. However, the CCT, WTW, and IOP values were not interchangeable with a single multifunctional unit for cataract surgery preoperative examination.

목차

Materials and Methods
Results
Discussion
References

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

Bo Yi Kim,Ikhyun Jun. (2022).Comparison of Anterior Segment Measurements with a New Multifunctional Unit and Five Other Devices. The Korean Journal of Ophthalmology, 36 (4), 338-349

MLA

Bo Yi Kim,Ikhyun Jun. "Comparison of Anterior Segment Measurements with a New Multifunctional Unit and Five Other Devices." The Korean Journal of Ophthalmology, 36.4(2022): 338-349

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제