Agreement between Two Swept-Source Optical Coherence Tomography Biometers and a Partial Coherence Interferometer

이용수 0

영문명
Agreement between Two Swept-Source Optical Coherence Tomography Biometers and a Partial Coherence Interferometer
발행기관
대한안과학회
저자명
Ji Young Moon Soo Chang Cho Hyun Jin Kim Roo Min Jun Kyung Eun Han
간행물 정보
『The Korean Journal of Ophthalmology』Vol.36 No.4, 326~337쪽, 전체 12쪽
주제분류
의약학 > 기타의약학
파일형태
PDF
발행일자
2022.08.31
4,240

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: To evaluate the level of agreement between ANTERION (Heidelberg Engineering, Heidelberg, Germany), OA-2000(Tomey, Nagoya, Japan), and IOLMaster 500 (Carl Zeiss AG, Jena, Germany). Methods: Fifty-one eyes of 51 patients were included in the study. Flat keratometry (K) and steep K, vector component of astigmatism (Jackson cross-cylinder at 0° and 90° [J0] and Jackson cross-cylinder at 45° and 135° [J45]), anterior chamber depth, and axial length were compared using the three devices. Repeated measures analysis of variance was conducted to compare the mean values of the biometrics. Pearson correlation test was conducted to analyze the correlations of the measured values, and a Bland-Altman plot was used to assess the agreement between the three devices. The predicted intraocular lens power of each device was compared to the others using the SRK/T, Haigis, Barrett Universal II, and Kane formulas. Results: All K values measured using ANTERION were flatter than those of other instruments. However, good agreement was observed for flat K (ANTERION - OA-2000; 95% limits of agreement [LoA], 0.86 diopters [D]) and steep K (ANTERION - OA- 2000; 95% LoA, 0.93 D) and OA-2000 - IOLMaster 500 (95% LoA, 0.93 D). J0 and J45 vector components of astigmatism were not statistically different; however, the agreements were poor between the devices (95% LoA ≥1.97 D). Anterior chamber depth values of ANTERION and OA-2000 were interchangeable (95% LoA, 0.15 mm). The axial length showed a high agreement (95% LoA ≤0.17 mm) among the three devices. The predicted intraocular lens powers of the three devices were not interchangeable regardless of formulas (95% LoA ≥1.04 D). Conclusions: Significant differences in ocular biometrics were observed between ANTERION and the other two devices. This study demonstrated that only axial length showed good agreement among devices.

목차

Materials and Methods
Results
Discussion
Supplementary Materials
References

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

Ji Young Moon,Soo Chang Cho,Hyun Jin Kim,Roo Min Jun,Kyung Eun Han. (2022).Agreement between Two Swept-Source Optical Coherence Tomography Biometers and a Partial Coherence Interferometer. The Korean Journal of Ophthalmology, 36 (4), 326-337

MLA

Ji Young Moon,Soo Chang Cho,Hyun Jin Kim,Roo Min Jun,Kyung Eun Han. "Agreement between Two Swept-Source Optical Coherence Tomography Biometers and a Partial Coherence Interferometer." The Korean Journal of Ophthalmology, 36.4(2022): 326-337

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제