본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

Calibration Update for the Measuring Total Nitrogen Content in Rice Plant Tissue Using the Near Infrared Spectroscopy

이용수 0

영문명
발행기관
한국작물학회
저자명
Young-Rip Kwon Young-Eun Song Dong-Chil Choi Jeong Ryu
간행물 정보
『한국작물학회지』제54권 제1호, 29~35쪽, 전체 7쪽
주제분류
농수해양 > 기타농수해양
파일형태
PDF
발행일자
2009.03.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

The aim of the present study was to update the calibration that is used for the measurement of the total nitrogen content in the rice plant samples by using the visible and near infrared spectrum. Before the equation merge, correlation coefficient of calibration equation for nitrogen content on each rice parts was 0.945 (Leaf), 0.928 (Stem), and 0.864 (Whole plant), respectively. In the cali-bration models created by each part in the rice plant under the various regression method, the calibration model for the leaf was recorded with relatively high accuracy. Among of those, the calibration equation developed by Partial least squares (PLS) method was more accurate than the Multiple linear regression (MLR) method. The calibration equation was sensitive based on variety and location variations. How-ever, we have merged and enlarged various of the samples that made not only to measure the nitrogen content more accurately, but also later sampling populations became more diversified. After merging, R2 value becomes more accurate and significantly to 0.950 (L.), 0.974 (S.), 0.940 (W.). Also, after removal of outlier, R2 values increased into 0.998, 0.995, and 0.997. In view of the results so far achieved, Standard error of prediction (SEP) and SEP (C) were reduced in the stem and whole plant. Biases were reduced in the leaf, stem as well as whole plant. Slopes were high in the stem. Standard deviation reduced in the stem but R2 was high in the stem and whole plant. Result was indicated that calibration equation make update, and updating robust calibration equation from merge function and multi-variate calibration.

목차

MATERIALS AND METHODS
RESULTS AND DISCUSSION
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

Young-Rip Kwon,Young-Eun Song,Dong-Chil Choi,Jeong Ryu. (2009).Calibration Update for the Measuring Total Nitrogen Content in Rice Plant Tissue Using the Near Infrared Spectroscopy. 한국작물학회지, 54 (1), 29-35

MLA

Young-Rip Kwon,Young-Eun Song,Dong-Chil Choi,Jeong Ryu. "Calibration Update for the Measuring Total Nitrogen Content in Rice Plant Tissue Using the Near Infrared Spectroscopy." 한국작물학회지, 54.1(2009): 29-35

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제