본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

Validation of an Infrared Camera System with a Joint Analysis Software as a Real Time Strength Training and Evaluation Tool

이용수 0

영문명
발행기관
대한운동학회
저자명
Jacob Frazier Jae Yom Cheryl Howe David Chelberg
간행물 정보
『아시아 운동학 학술지』제20권 제3호, 52~56쪽, 전체 5쪽
주제분류
예술체육 > 체육
파일형태
PDF
발행일자
2018.07.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

OBJECTIVES Athletic performance and injury prevention are important for athletes and coaches. Different types of movement analyses have been created to aid in injury prevention and performance. The reliability of the Microsoft Kinect™ for movement analysis has not been widely tested. If reliable and accurate it could decrease the cost and time necessary for movement analysis. The purpose of this study was to determine if the Microsoft Kinect™ is an accurate measure of knee displacement during the parallel squat when com-pared to the Dartfish Team Pro Software 6.0. METHODS Twenty nine healthy recreational athletes participated in the study and used the Dartfish Team Pro Software 6.0 to validate the Microsoft Kinect™ as a tool to measure knee displacement. Subjects per-formed a parallel squat with a 2.1m long dowel rod. This exercise was used to compare value between sys-tems. The intraclass correlation coefficient and paired-samples t-test were used to compare Dartfish Team Pro Software 6.0 and Microsoft Kinect™. Intrarater reliability of each system was also assessed. RESULTS There were 29 participants in the study. The interclass correlation coefficient for Dartfish Team Pro Software 6.0 and Microsoft Kinect™ showed that the Microsoft Kinect™ had a high-reliability ICC = 0.96. Intrarater reliability for Kinect™ and Dartfish were .98 and .99, respectively. The mean difference between systems for measured knee displacement was 1.06 cm. The mean for the Microsoft Kinect™ was 49.11 ± 1.9 and 50.16 ± 96 for the Dartfish (p > 0.05). CONCLUSIONS The Microsoft Kinect™ is reliable against the Dartfish Team Pro Software 6.0 as a tool to measure knee displacement using the parallel squat. It appears for healthy young adults, the Microsoft Kinect™ is reliable for movement analysis.

목차

Introduction
Methods
Results
Discussion
Conclusions
Acknowledgments
Conflicts of Interest
References

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

Jacob Frazier,Jae Yom,Cheryl Howe,David Chelberg. (2018).Validation of an Infrared Camera System with a Joint Analysis Software as a Real Time Strength Training and Evaluation Tool. 아시아 운동학 학술지, 20 (3), 52-56

MLA

Jacob Frazier,Jae Yom,Cheryl Howe,David Chelberg. "Validation of an Infrared Camera System with a Joint Analysis Software as a Real Time Strength Training and Evaluation Tool." 아시아 운동학 학술지, 20.3(2018): 52-56

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제