본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

서울시 초등학교 실내 먼지 중 프탈레이트 오염실태 조사

이용수 74

영문명
Phthalates Contamination in Indoor Dust in Elementary Schools in Seoul: A Pilot Study
발행기관
한국환경보건학회
저자명
이영선(Young-Sun Lee) 최인자(Inja Choi)
간행물 정보
『1. 한국환경보건학회지』제46권 제5호, 548~554쪽, 전체 7쪽
주제분류
공학 > 환경공학
파일형태
PDF
발행일자
2020.10.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Objectives: This study is to examine the polyvinyl chloride (PVC) materials in elementary school classrooms and libraries in Seoul, and to investigate phthalate contamination in indoor dust. Methods: PVC material was identified for building materials and furniture using portable x-ray fluorescence (XRF). Phthalates in dust samples (n=19) were extracted by ultrasonic extraction using cyclohexane and analyzed by GC-MS. Results: Diethyl phthalate (DEP), di-n-butyl phthalate (DBP), and Bis (2-ethylhexyl) phthalate (DEHP) were found in all collected dust samples (n=19), and diisonyl phthalate (DINP) was detected in all except for one sample (n=18). The concentration of DEHP (median: 2190 mg/kg) and DINP (2960 mg/kg) were higher than other compounds, suggesting that there are many products in the school that used these compounds. When comparing the phthalate concentration in the classroom (n=11) and library dust (n=8), the total concentration in the classroom (median: 10000 mg/kg) was higher than that in the library (8030 mg/kg). DEHP was the dominant compound in the library. The library is relatively more equipped with PVC furniture (n=83) and most floors are also identified as PVC material, suggesting that floors and furniture made of PVC materials are main sources of DEHP contamination. Conclusions: This study is a pilot survey for investigating phthalate contamination in elementary schools. As a result of the survey, phthalate contamination in elementary school was confirmed. However, further study requires risk assessment of children through analysis of phthalate metabolites in children based on sufficient number of samples and information about the site.

목차

I. 서 론
II. 재료 및 방법
III. 결 과
IV. 고 찰
V. 결 론
References

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

이영선(Young-Sun Lee),최인자(Inja Choi). (2020).서울시 초등학교 실내 먼지 중 프탈레이트 오염실태 조사. 1. 한국환경보건학회지, 46 (5), 548-554

MLA

이영선(Young-Sun Lee),최인자(Inja Choi). "서울시 초등학교 실내 먼지 중 프탈레이트 오염실태 조사." 1. 한국환경보건학회지, 46.5(2020): 548-554

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제