Evaluation on Usefulness of BMI Application to Urological CT Examination
이용수 36
- 영문명
- 비뇨기계 CT 검사 시 체질량 지수 적용의 유용성 평가
- 발행기관
- 한국방사선학회
- 저자명
- Hyeon-jin Kim(김현진) In-chul Im(임인철)
- 간행물 정보
- 『한국방사선학회 논문지』 제12권 제2호, 185~191쪽, 전체 7쪽
- 주제분류
- 공학 > 기타공학
- 파일형태
- 발행일자
- 2018.04.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.
국문 초록
The purpose of this study was to evaluate the usefulness of BMI application to Urography CT by applying different tube voltages in accordance with body mass index. Group A (n = 38) with body mass index of lower than 25 was examined with tube voltage of 100 kVp while Group B (n = 45) with a BMI of 25 and higher was examined with tube voltage of 120 kVp. C group (n = 37) with body mass index (BMI) of lower than 25 was examined with tube voltage of 120kVp. Although the difference in average dose between group A (100 kVp) and group C (120 kVp) with low body mass index (BMI) of lower than 25 was 214.8 mGy · cm, there was no significant difference in qualitative evaluation and, compared with patient group with body mass index of 25 and higher, results obtained were rather good. Therefore, this study verified that the tube voltage of lower than 100kVp does not have adverse effect on the quality of image for patients with body mass index (BMI) of lower than 25.
영문 초록
본 연구에서는 체질량 지수에 따라 각기 다른 관전압을 적용하여 비뇨기계 CT 검사 시 체질량 지수 적용의 유용성을 평가하고자 하였다. A그룹(n=38)은 체질량 지수가 25 이하이며 관전압 100 kVp로 검사하였고 B그룹(n=45)은 체질량 지수가 25 이상이며 관전압 120kVp로 검사하였다. C그룹(n=37)은 체질량 지수가 25 이하이며 관전압 120kVp로 검사하였다. 체질량 지수가 25 이하로 낮은 A그룹(100 kVp)과 C그룹(120kV p)의 두 그룹간 평균 선량의 차이는 214.8 mGy·cm의 차이를 나타내었으나 정성적 평가에서는 큰 차이가 없음을 확인할 수 있었으며 체질량 지수가 25이상인 환자군과 비교하여서는 오히려 좋은 결과를 확인할 수 있었다. 따라서 체질량 지수가 25 이하로 낮은 환자는 관전압을 100 kVp 로 낮추어 촬영하여도 영상의 질에는 부정적인 영향을 주지 않음을 알 수 있다.
목차
I. INTRODUCTION
II. MATERIAL AND METHODS
III. RESULT
IV. DISCUSSION
V. CONCLUSION
해당간행물 수록 논문
- A Study on the Performance Evaluation of Standard Gamma Irradiation System Using Monte Carlo Code
- Comparison of Shear Wave Elastography and Pathologic Results Using BI - RADS Category for Breast Mass
- The Study of a Diagnostic Algorithm for the Quantitative Evaluation of Stress Urinary Incontinence
- Fractional Anisotropy of Diffuse Tensor Imaging of Normal Subjects in the Regions of the Brain White Matter According to Age and Body Mass Index (BMI)
- Status of Nuclear Power Plant Decommissioning Cost Analysis in USA
- Assessment of Magnetic Resonance Image Quality For Ferromagnetic Artifact Generation: Comparison with 1.5T and 3.0T.
- A Study on Measurement of Gamma-ray Spectrum for the Natural Tungsten nuclear reaction by using KOMAC proton Linear Accelerator
- Perception of Radiological Technologists on Enacting of the Radiological Technologist Act in Korea
- Relationship between 18 FDG Uptake Rate and CT Number in Fatty Liver on PET-CT
- Application of professorㆍlearning model customized for flipped learning for enhancing basic ability of work - Focused on freshman students in radiology department of specialized colleges
- Analysis of Differences in Fractional Anisotropy of Diffusion Tensor Images of Basal Ganglia in the Brain Gray Matter according to Smoking
- Evaluation of Absorbed Dose According to the Nanoparticle in Prostate Cancer Brachytherapy
- A Study on the Image Quality According to the Change of Flip Angle in Flow-Related Enhancement Magnetic Resonance Angiography
- Analysis of Shielding Effect of Lead and Tungsten by use of Medical Radiation
- Measurement and Monte Carlo Simulation evaluation of a Compton Continuum Suppression with low level soil Sample
- A Study on the Presentation of Entrance Surface Dose Model using Semiconductor Dosimeter, General Dosimeter, Glass Dosimeter: Focusing on Comparative Analysis of Effective Dose and Disease Risk through PCXMC 2.0 based on Monte Carlo Simulation
- Evaluation on Usefulness of BMI Application to Urological CT Examination
- Dose Assessment of the Eye of the Operator in the Field of Angiography and Interventional Radiography
- A Study on Perception by Examinees of the Dental Hospital Institutions about Exposure to Radioactivity
- 한국방사선학회 논문지 제12권 제2호 목차
- Noise Changes in Image Plate
참고문헌
관련논문
공학 > 기타공학분야 BEST
더보기공학 > 기타공학분야 NEW
- 고분해능 및 고민감도를 위한 준 블록 섬광체를 사용한 네 층의 반응 깊이 측정 검출기 설계
- 기분장애 환자의 대뇌 피질 두께 측정에 관한 연구
- 양방향 흐름 팬텀 모델에서 탄산수의 도플러 유체 효과 연구
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!