국문 초록
Pelvic floor muscle is the main sub-system that maintains urinary continence. The weakness of pelvic floor muscles causes the stress urinary incontinence, and therefore the degree of functioning of pelvic floor muscles could be used as an index to assess the degree of stress urinary incontinence. In this study, the quantitative diagnosis algorithm was proposed to estimate the degree of stress urinary incontinence (SUI) by measuring the contraction pressure of pelvic floor muscle. For these reason, the contraction pressure measurement system from pelvic floor muscle was developed, and the measuring protocol was suggested to analysis the obtained data. As the results of clinical test, the proposed diagnosis algorithm shows the 80% of accuracy, and 20% of false positive diagnosis. On the other hand, false negative results were not confirmed. Consequentially, we thought that the proposed urinary incontinence diagnosis algorithm can quantitatively diagnose the progression of the stress urinary incontinence and it can be used for the development of the incontinence diagnosis system.
영문 초록
골반저근은 골반기관을 지지하는 기능을 가지고 있으며 요자제를 유지하는 여성의 주요 하부조직이다. 골반저근의 약화는 복압성 요실금의 원인이 되는데, 이러한 골반저근의 기능 정도는 복압성 요실금의 병증 정도를 평가하는 지표로 사용될 수 있다. 이에 본 연구에서는 골반저근의 수축 압력을 측정하여 복압성 요실금의 병적 진행정도를 정량적으로 진단할 수 있는 요실금 진단 알고리즘을 제안하였다. 이를 위하여 골반저근의 수축압력 정보를 측정할 수 있는 시스템을 제작하였으며, 측정된 데이터의 특징 분석을 위한 측정 프로토콜을 제안하였다. 복압성 요실금 환자로부터 획득한 데이터를 이용하여 5개의 진단 파라미터를 추출하였으며, 이를 이용한 진단 알고리즘을 구현하였다. 임상시험을 통하여 진단 알고리즘의 정확성을 평가한 결과 80%의 정확성을 보였으며, 20%의 위양성 진단 결과를 보였다. 반면에 위음성 진단 결과는 확인되지 않았다. 본 연구에서 제안한 요실금 진단 알고리즘은 복압성 요실금의 병적 진행 정도를 정량적으로 진단할 수 있으며, 요실금 진단 시스템 개발에 활용될 수 있을 것으로 판단된다.
목차
I. INTRODUCTION
II. MATERIALS AND METHOD
III. RESULTS AND DISCUSSION
IV. CONCLUSION
키워드
해당간행물 수록 논문
- A Study on the Performance Evaluation of Standard Gamma Irradiation System Using Monte Carlo Code
- Comparison of Shear Wave Elastography and Pathologic Results Using BI - RADS Category for Breast Mass
- The Study of a Diagnostic Algorithm for the Quantitative Evaluation of Stress Urinary Incontinence
- Fractional Anisotropy of Diffuse Tensor Imaging of Normal Subjects in the Regions of the Brain White Matter According to Age and Body Mass Index (BMI)
- Status of Nuclear Power Plant Decommissioning Cost Analysis in USA
- Assessment of Magnetic Resonance Image Quality For Ferromagnetic Artifact Generation: Comparison with 1.5T and 3.0T.
- A Study on Measurement of Gamma-ray Spectrum for the Natural Tungsten nuclear reaction by using KOMAC proton Linear Accelerator
- Perception of Radiological Technologists on Enacting of the Radiological Technologist Act in Korea
- Relationship between 18 FDG Uptake Rate and CT Number in Fatty Liver on PET-CT
- Application of professorㆍlearning model customized for flipped learning for enhancing basic ability of work - Focused on freshman students in radiology department of specialized colleges
- Analysis of Differences in Fractional Anisotropy of Diffusion Tensor Images of Basal Ganglia in the Brain Gray Matter according to Smoking
- Evaluation of Absorbed Dose According to the Nanoparticle in Prostate Cancer Brachytherapy
- A Study on the Image Quality According to the Change of Flip Angle in Flow-Related Enhancement Magnetic Resonance Angiography
- Analysis of Shielding Effect of Lead and Tungsten by use of Medical Radiation
- Measurement and Monte Carlo Simulation evaluation of a Compton Continuum Suppression with low level soil Sample
- A Study on the Presentation of Entrance Surface Dose Model using Semiconductor Dosimeter, General Dosimeter, Glass Dosimeter: Focusing on Comparative Analysis of Effective Dose and Disease Risk through PCXMC 2.0 based on Monte Carlo Simulation
- Evaluation on Usefulness of BMI Application to Urological CT Examination
- Dose Assessment of the Eye of the Operator in the Field of Angiography and Interventional Radiography
- A Study on Perception by Examinees of the Dental Hospital Institutions about Exposure to Radioactivity
- 한국방사선학회 논문지 제12권 제2호 목차
- Noise Changes in Image Plate
참고문헌
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!