국문 초록
영문 초록
This study was carried out to evaluate student exposures to dust in classroom of middle schools. A total of four schools, such as two in an urban and two in a rural area, were selected for this study.
In this study, airborne dust concentrations were measured during a period from July 8 to July 18, 1986. Additional measurements of dust concentrations were conducted from November 4 to 7, 1986 to compare the results by seasonal variation.
The results of this study were as follows.
1. Respirable dust concentrations were measured by both filtration method (C mg/m³ and Digital Aerosol Monitor (cpm) to calculate anexchange factor K. K- value was 0.159 as follows.
K=c/cpm= 2.71/17.09=0.159
2. In summer when windows were opened, the concentrations of airborne respirable dusts measured by filter sampling method were 0.54-1.37 mg/m³ in the morning and 0.79-1.75 mg/m³ in the afternoon. Thus, higher levels were indicated in the afternoon. Meanwhile, the concentrations of airborne respirable dusts measured in winter were approximately twice as high as those in summer.
3. The highest dust concentrations were determined in School D which is a coeducational school with classroom of concrete floor. Walking roads in School D were not paved and students did not wear indoor-shoes. Dust levels in School D were approximately twice as high as levels in School B. All of the measured dust levels in four schools exceeded Korean Standard for outdoor air, 0.3 mg/m³ for 24 hours. Results by Digital Aerosol Monitor indicated that there was no significant difference in dust levels among grades. The concentration of airborne dusts in the classroom was 1.5-3.0 times higher than that in the hall way. The concentration of airborne dusts during recess was 1.3-1.6 times higher than that during class. In winter, the dust concentrations during clean-up exceeded the permissible exposure limit, 10 mg/m³ (as total dusts), for occupational exposures.
4. The concentrations of total dusts measured in winter were 1.5-2.4 times higher than those of respirable dusts measured simultaneously.
목차
Ⅰ. 서 론
Ⅱ. 조사대상 및 방법
Ⅲ. 성적 및 고활
키워드
해당간행물 수록 논문
참고문헌
관련논문
공학 > 환경공학분야 BEST
더보기공학 > 환경공학분야 NEW
- 도심환경교통(Urban Air Mobility, UAM) 도입에 따른 소음 문제에 대한 시론 -UAM 소음의 특성과 잠재적 건강영향: 연구 방향 및 관리를 위한 정책적 고려사항-
- 광주지역 공공수역의 미생물 군집 다양성 및 항생제 내성에 관한 연구
- 서울시 관악구 도림천 복개 정도에 따른 환경 악취 요인 분석
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!