본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

病院廢水의 特性과 處理에 關한 鼎究

이용수 5

영문명
Studies on the Wastewater of General Hospital and It’s Treatment - Effects of Disinfectants on Activated Sludge Process -
발행기관
한국환경보건학회
저자명
羅圭煥(Kyu Hwan Ra) 玉致相(Chi Sang ok)
간행물 정보
『1. 한국환경보건학회지』제10권 제1호, 13~20쪽, 전체 8쪽
주제분류
공학 > 환경공학
파일형태
PDF
발행일자
1984.04.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

The hospital wastewaters have to be so disposed as to prevent disease and to protect water resources from hazardous substances; disinfectants, medicines, and chemicals. Polyvinylpyrrolidone-iodine complex (po꺼done-iodine) is widely used in the hospital as one of disinfectants. πùs study was carried out to manifest the effect of disinfectants in growth of activated sludge in treatment of the hospital wastewater by the activated sludge process. The results are as follow. 1. An average water quality of the hospital wastewater showed 7.2 in pH, 3.2 ppm in 00, 293.3 ppm in SS, 96.0 ppm in 800, 151 .1 ppm in COO, 0.4 ppm in povidone-iodine, 0.5 ppm in phenols, 5.4 ppm in surfactants, 1.6 ppm in o-phosphate, 4.6 ppm in NH3 -N, 249 x 104 counts/l00 mQ in coliform group organisms, and 1,369 x 101 counts/mQ in general counts of bacteria. And wastewater amounts discharged per bed was ca1culated 70 Q/d/bed. 2. In batch culture activated sludge process, each of cresol and podone-iodine was not effected in less than 0.1 ppm concentration, but the more concentration, the more inhibit the growth rate of activated sludge. In the mixture of two disinfectants, the growth was more inhibited the effect of single disinfectants. So that this reaction is considered as addition effect of two disinfectants. 3. The removal rates of the disinfectants by continuous cu1ture activated sludge process were 77 .6% in 0.4 ppm povidone-iodine, and in 80D was 85.6%. 4. It is desirable that the hospital wastewater is planed in order to be discharged to two system separately, sewer from life system and wastewater from medica1 system. From those results, it has been conc1uded that the hospital wastewater has to be treated safely by the activated sludge process.

목차

1 . 緖 論
11. 實驗缺課 및 方法
ill. 結果 및 考察
lV. 結論

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

羅圭煥(Kyu Hwan Ra),玉致相(Chi Sang ok). (1984).病院廢水의 特性과 處理에 關한 鼎究. 1. 한국환경보건학회지, 10 (1), 13-20

MLA

羅圭煥(Kyu Hwan Ra),玉致相(Chi Sang ok). "病院廢水의 特性과 處理에 關한 鼎究." 1. 한국환경보건학회지, 10.1(1984): 13-20

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제