국문 초록
영문 초록
Objectives: The purpose of this study was to identify the stains causing infections in dental clinics by analyzing bacterial contamination, as well as to suggest improvements for infection control in dental clinics.
Methods: In this study, a questionnaire survey of 47 dental hospitals and clinics located in Gyeonggi-do and Incheon, South Korea was administered from June 2013 to September 2013 and used to investigate the practice rates of infection control by dental hygienists and to analyze the bacterial contamination levels in dental offices.
Results: In the studied institutions, the bacterial contamination levels of water lines were 20.9×10 3 colony forming units (CFU/mL) for three-way syringes, 12.7×10 3 CFU/mL for high-speed handpieces and 9.8×10 3 CFU/ mL for gargling water. The bacterial contamination levels of surfaces were 44.9×10 3 CFU/mL in cuspidors, higher than in unit chairs (2.9×10 3 CFU/mL) and light handles (6.7×10 3 CFU/mL). The mean bacterial cell count of water lines and surfaces was relatively high in all establishments founded 11 years ago or more, and the mean bacterial cell count of waterline handpieces was 6.27×10 3 CFU/mL in establishments founded between one and five years ago, 11.16×10 3 CFU/mL six to ten years ago and 20.04×10 3 CFU/mL 11 years ago or more, which suggests that earlier foundation is associated with higher bacterial contamination levels with a statistical difference (p<0.01). Similarly, the mean bacterial cell count of cuspidors using water from water lines was also 70.16×10 3 CFU/mL in at least 11-year-old establishments, statistically significantly higher among in one- to fiveyear-old (4.61×10 3 CFU/mL) and six- to ten-year-old clinics (47.89×10 3 CFU/mL) (p<0.05).
Conclusion: This study may be utilized to improve the bacterial contamination levels in dental offices by controlling the characteristics and environmental factors of dental offices that affect the microbial contamination of waterlines and surfaces in such institutions.
목차
I. 서 론
II. 연구대상 및 방법
III. 연구결과
IV. 고 찰
V. 결 론
해당간행물 수록 논문
참고문헌
관련논문
공학 > 환경공학분야 BEST
더보기공학 > 환경공학분야 NEW
- 도심환경교통(Urban Air Mobility, UAM) 도입에 따른 소음 문제에 대한 시론 -UAM 소음의 특성과 잠재적 건강영향: 연구 방향 및 관리를 위한 정책적 고려사항-
- 광주지역 공공수역의 미생물 군집 다양성 및 항생제 내성에 관한 연구
- 서울시 관악구 도림천 복개 정도에 따른 환경 악취 요인 분석
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!