본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

사체의 장골에서 수용부 형성방법에 따른 임플란트 일차 안정성

이용수 7

영문명
PRIMARY STABILITY OF IMPLANTS IN ILIUM OF CADAVER BY THE METHODS OF RECIPIENT SITE PREPARATION
발행기관
대한구강악안면외과학회
저자명
심정우(Jung-Woo Sim) 조진용(Jin-Yong Cho) 국민석(Min-Suk Kook) 박홍주(Hong-Ju Park) 오희균(Hee-Kyun Oh)
간행물 정보
『대한구강악안면외과학회지』대한구강악안면회과학회지 제34권 제2호, 180~186쪽, 전체 7쪽
주제분류
의약학 > 내과학
파일형태
PDF
발행일자
2009.04.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: This study was performed to evaluate the effect of the implant recipient site preparation methods on primary stability of implants with the instruments of OsstellTM and Periotest in the iliac bone of cadaver. Methods and materials: The 8 iliac bones in 4 cadavers and implants treated with resorbable blasting media (RBM) were used. Periotest (Simens AG, Germany) and OsstellTM(Model 6 Resonance Frequency Analyser: Integration Diagnostics Ltd., Sweden) were used to measure primary stability of implants. Implants were inserted into the iliac crest of the cadaver. In control group, the recipient site was prepared according to the manufacturer’s recommendation: 1.8 mm guide drill, 2.0 mm initial drill, 2.7 mm pilot drill, 2.7 mm twist drill, 3.0 mm twist drill, 3.3 mm pilot drill, 3.3 mm twist drill, and 3.3 mm countersink drill as well as tapping drill were used in order. In the group 1, implant recipient sites were prepared by sequentially drilling from 1.8 mm guide drill to 3.0 mm twist drill and then inserted implants without countersinking and tapping. In the group 2, implant recipient sites were prepared to 3.0 mm twist drill and countersink drill and then inserted implants without tapping. In the group 3, the sites were prepared to 3.0 mm twist drill and countersink drill as well as tapping drill. In the group 4, the sites were prepared to 3.3 mm twist drill. In the group 5, the sites were prepared to 3.3 mm twist drill and countersink drill. A total of 60 implants were placed (n=10). The stability was measured using OsstellTM and Periotest mesiodistally and buccolingually. To compare the mean stability of each group statistically, One-way ANOVA was used and correlation of instrument were analyzed using SPSS 12.0. The results obtained were as follows; 1. The stability of group 1 measured using OsstellTM and Periotest buccolingually showed the highest, and there are significant difference statistically between control group and experimental group 1,2,4 in each instruments respectively (p<0.05). 2. The stability of group 1 measured using OsstellTM and Periotest mesiodistally showed the highest. There are significant difference statistically between control group and all experimental groups in OsstellTM, and between control group and experimental group 1,2,3,4 (p<0.05). 3. There are high correlation between the measurements of OsstellTM and Periotest (p<0.05). Conclusion: These results indicate that the primary stability of implant can be obtained by the recipient sites preparation with smaller diameter drill than that of implant or minimal drilling.

목차

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

심정우(Jung-Woo Sim),조진용(Jin-Yong Cho),국민석(Min-Suk Kook),박홍주(Hong-Ju Park),오희균(Hee-Kyun Oh). (2009).사체의 장골에서 수용부 형성방법에 따른 임플란트 일차 안정성. 대한구강악안면외과학회지, 34 (2), 180-186

MLA

심정우(Jung-Woo Sim),조진용(Jin-Yong Cho),국민석(Min-Suk Kook),박홍주(Hong-Ju Park),오희균(Hee-Kyun Oh). "사체의 장골에서 수용부 형성방법에 따른 임플란트 일차 안정성." 대한구강악안면외과학회지, 34.2(2009): 180-186

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제